  • Page 1 Sonostat User manual...
  • Page 2 Sonostat The gbo Medizintechnik AG of has taken care in preparation of this manual, but makes no expressed or implied warranty of any kind and assume no responsibility for errors or omissions. All rights reserved. No part of this manual may be reproduced, in any form or by any means (electronic, mechanical, or otherwise) without the prior written permission of the gbo Medizintechnik AG.
  • Page 3: Table Of Contents

    Cleaning the unit ..................22 5.3.2 Disinfection of the ultrasound head ............22 6 WARNINGS AND SAFETY PRECAUTIONS ......... 23 7 CONTRAINDICATIONS ................. 24 8 EXPLANATION OF SYMBOLS USED ..........26 9 TECHNICAL DATA ................27 gbo Medizintechnik AG Version 1.2...
  • Page 4 Sonostat 10 ACCESSORIES ..................28 11 TROUBLESHOOTING ................29 12 APPENDIX ..................... 30 INDEX ......................33 gbo Medizintechnik AG Version 1.2...
  • Page 5 Sonostat Warnings and Notes Warning! Warnings which must be observed by all means ! Attention! Observe the instructions for use ! Note! Information that will facilitate the work. gbo Medizintechnik AG Version 1.2...
  • Page 6: Introduction

    The operation of the device must be performed only by trained medical professionals. 1.3 Description The Sonostat is an ultrasonic therapy equipment for continuous and pulsed sound. All applications are easy and safe. The ultrasonic waves are generated by means of the two main components of the generator and the treatment head.
  • Page 7 Sonostat The Sonostat can apply ultrasonic frequencies of 1 and 3.3 MHz. Basically, the higher the ultrasonic frequency, the lower the penetration of the ultrasound. Accordingly, we recommend the use of 3.3 MHz at near-surface indications. In addition the Sonostat offers indication programs. By selecting the desired indication, the appropriate therapy time, ultrasound power, frequency and constant or pulsed ultrasound are selected automatically.
  • Page 8: Start Of Operation

    The device is not made for outdoor operation. The Sonostat corresponds to the regulations DIN EN 60601. It is a device of protection class I. Within the scope of the Medical Device Directive (MDD) the ultrasound therapy device belongs to class IIa.
  • Page 9: Placing Out Of Operation

    Sonostat Turn on the Sonostat with the power button on the rear panel. ON/Off switch AC power connector with fuse holder Stimulation Input jack The Sonostat is equipped with a SD card slot, located to the right of the display. This port is intended for service purposes only.
  • Page 10: Operation

    Sonostat 3 Operation The Sonostat has a touchscreen display, a knob, an ON/OFF switch and sockets for two ultrasound heads. The Sonostat is being operated via the control panel of the touch screen. Touchscreen Display Knob Ultrasound head holder 3.1 Overview 3.1.1 Touchscreen display...
  • Page 11: Power Regulator

    Error in head flashing Warning! Always handle all applicators with care. Do not let ultrasonic heads fall down. Remove gel residues directly after treatment completely from the active metal surface of the ultrasound head. gbo Medizintechnik AG Version 1.2...
  • Page 12: Panels Home Screen

    Button Head left Head right Time Selection Favourite list Selection Individual Settings Selection therapies Selection Indications Button Button Button Coupling settings Direct help head heater control Detailed Settings of Therapy therapy parameters start / stop gbo Medizintechnik AG Version 1.2...
  • Page 13: Panels Selection Indication

    Home screen without applying their own therapy Return Home screen with assumption of the own therapy Delete the selected entry Rename the selected entry Parameters List of own therapies selected list entry in alphabetical order gbo Medizintechnik AG Version 1.2...
  • Page 14: Direct Help

    Sonostat 3.2 Direct help The user is guided during use of Sonostat by the software. Due to the direct help the selected keys are explained directly on the screen. To start the Direct help function, press the Button "?" on the screen and then press the button to which you want information.
  • Page 15: Settings

    Sonostat 3.3 Settings Use the “Settings” key to access the setup menu of the Sonostat. In this menu, parameters such as languages, output of different sounds, i. e. for the end of treatment and various treatment parameters are defined. The access to the service menu is also located in the settings menu.
  • Page 16: Therapy

    (e.g. slipped disk with sciatica, foci). It is frequently the case that structure-changing processes can be favorably influenced by an extended therapy of up to 40 treatment sessions. gbo Medizintechnik AG Version 1.2...
  • Page 17: Choice Of Therapy - By Own Therapy

    4.3 Choice of therapy - by indications In Sonostat an indication menu is integrated. This provides a list of programs with pictures indication specifying parameters (ultrasound frequency, pulse ratio, intensity and time).
  • Page 18: Operating A Treatment

    In the settings it can be specified if the therapy time is running or stopped when you lift the ultrasound head. (Coupling control) The ultrasound head is freely interchangeable. When the device is switched on or the ultrasound head is inserted, each head is calibrated individually. gbo Medizintechnik AG Version 1.2...
  • Page 19: Combination Therapy With Current Stimulation

    The connection of the devices is performed by the connection of the current stimulator output to the input jack which is located on the back side of the Sonostat. The device's internal flow path is activated only for the selected ultrasound head.
  • Page 20: Procedure For Combination Therapy

    White plugs has a positive polarity in the primary position, while the counter electrode - the metallic surface of transducer - is negative. Connect the white plug to the patient cable to the neutral electrode and the black one with the Sonostat. Apply the neutral electrode.
  • Page 21: Maintenance

    Sonostat 5 Maintenance Functionality, reliability and safety characteristics of the Sonostat are guaranteed only if the device is handled in accordance with the operating instructions. Safety control, maintenance work, repair work and modifications must only be carried out by the manufacturer or by service agents authorized by him. In case of a failure, parts which influence the safety of the device must only be replaced by original spare parts of the manufacturer.
  • Page 22: Cleaning, Disinfection And Care

    Before cleaning or disinfecting always pull out the mains plug from the wall outlet! The Sonostat is suitable for wipe disinfection. It is important to ensure that no liquids get into the unit. Do not wet plugs or sockets. The device must not be sprayed for cleaning or disinfecting.
  • Page 23: Warnings And Safety Precautions

    The unit is not designed to be operated in places with the inherent risk of explosions. If it is used in dangerous areas of anesthesia departments, the possibility of an explosion cannot be excluded. discernible malfunction, immediately contact Medizintechnik AG or an authorized service center in conjunction. gbo Medizintechnik AG Version 1.2...
  • Page 24: Contraindications

    Vascular disease of the extremities (thrombophlebitis, thrombosis, varicose veins) Disorders of coagulation of blood Changes in the skin, particularly in infectious diseases and Hautnaevi (birthmarks) and open wounds Inflammation of the skin (caused by cosmetics) Epilepsy gbo Medizintechnik AG Version 1.2...
  • Page 25 This list does not claim to be complete. In individual cases, always the doctor must decide about contraindications and treatment criteria. In all discernible malfunction, contact gbo Medizintechnik AG or an authorized gbo Medizintechnik AG service contact immediately. gbo Medizintechnik AG...
  • Page 26: Explanation Of Symbols Used

    , max. 100 mA This appliance is labeled in accordance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (waste electrical and electronic equipment WEEE). The disposal at the end of its useful life, the manufacturer accepts. gbo Medizintechnik AG Version 1.2...
  • Page 27: Technical Data

    To maintain the leakage current limits it is not allowed to repair or replace components on the PCBs. The IEC connector is used for all-pole disconnection from the mains. gbo Medizintechnik AG reserves the right to change design and specifications without prior notice.
  • Page 28: Accessories

    026-0-3050 Holder for ultrasound gel bottle 026-0-3020 The picture shows the trolleys for the Sonostat It consists of the basic rack and the Sonostat additional module Note! Use only original accessories to ensure the safe operation of the appliance. The ultrasonic heads can be freely exchanged. The unit automatically adjusts itself to the relevant properties of the ultrasound head.
  • Page 29: Troubleshooting

    Please note that the unit must be placed on a plane horizontal surface. The device should neither be placed in front of radiators nor should it be covered with pillows or blankets while in operation. Do not cover the ventilation slots on the bottom of the unit either. gbo Medizintechnik AG Version 1.2...
  • Page 30: Appendix

    Technical support may be obtained by the manufacturer, dealers or service authorized by the manufacturer. The product’s duration of life as scheduled by the manufacturer is 10 years. Sonostat is an electronic device. For its disposal the according regulations for electronic devices have to be observed.
  • Page 31 Power frequency magnetic fields should magnetic field, be at levels characteristic of a typical IEC 61000-4-8 location in a typical commercial or hospital environment. Note: U is the a.c. mains voltage prior to application of the test level. gbo Medizintechnik AG Version 1.2...
  • Page 32 Separation distance according to the transmission frequency the transmitter 150 kHz to 80 80 MHz to 800 800 MHz to 2,5 GHz d=2,3 P d=1,2 P d=1,2 P 0,01 0,12 0,12 0,23 0,38 0,38 0,73 gbo Medizintechnik AG Version 1.2...
  • Page 33: Index

    Technical data 27 Therapy 16 Troubleshooting 29 Home screen 12 ultrasonic heads 11 indication 13 installation 8 Intended use 6 Warning 19 warnings 8, 23 Warnings 23 mains voltage 8 Maintenance 21 Operation 10 Overview 10 gbo Medizintechnik AG Version 1.2...