Reset To Factory Settings - Riello Vokera Easi-Flo LE Installation & Servicing Instructions Manual

Table of Contents

Advertisement

4
Gas Type
Flow Indicator Type
5
Domestic hot water start wait time
6
Domestic hot water circuit maximum setpoint
11
20 Induced draught protection function
Domestic hot water thermostat operation
40
Displaying domestic hot water input temperature
41
Displaying domestic hot water flow rate
42
Exiting the menu
rt
Resetting factory settings
rs
Pressing the MENU (B) key confirms the values set.
To exit the TECHNICAL MENU press the "+" or "-" key until "rt" (return)
is displayed. Pressing the MENU (B) key to return to the USER MENU.
Pressing the ON-OFF/RESET (A) key you pass to the OFF state.
If no action is taken, once 2 minutes have passed the appliance exits
the menu and returns to the normal operation screen.
Table of parameters
Nr.
PARAMETER DESCRIPTION
PAR
2
Selecting water heater output/capacity
4
Selecting methane/LPG
5
Selecting flow switch/flow indicator
6
Domestic hot water start wait time
11
maximum setpoint of domestic hot water circuit
20
Induced draught protection function
40
Type of domestic hot water thermostat operation
41
Displaying domestic hot water input temperature
42
Displaying domestic hot water flow rate
rt
Exiting the menu
rs
Resetting factory settings

5.18 Reset to factory settings

From the parameters menu, selecting "rs" allows you to reset the bo-
ard parameters to the factory settings (Reset to factory settings).
Pressing the MENU (B) key displays two underscores. Press the "-"
key until the two underscores shift up. Press the "+" key to return to
factory settings.
If you press the MENU (B) key instead of the "+" key the operation is
annulled and you return to the previous menu.
To exit the TECHNICAL MENU press the "+" or "-" key until "rt" (return)
is displayed, at this point pressing the MENU (B) key returns you to the
USER MENU.
Pressing the ON-OFF/RESET (A) key you pass to the OFF state.
If no action is taken, once 2 minutes have passed the appliance exits
the menu and returns to the normal operation screen.
b
If you are replacing the electronic board it is necessary to set the
parameters 2 (11-13-17) and 4 (methane - lpg) depending on the
type of water heater used.
UNIT OF
MEA-
MIN
MAX
SURE-
MENT
l/min
s
0,5
10
°C
36
65
0
1
°C
5.19 Reset to factory settings
From the parameters menu, selecting "rs" allows you to reset the bo-
ard parameters to the factory settings (Reset to factory settings).
Pressing the MENU (B) key displays two underscores. Press the "-"
key until the two underscores shift up. Press the "+" key to return to
factory settings.
If you press the MENU (B) key instead of the "+" key the operation is
annulled and you return to the previous menu.
To exit the TECHNICAL MENU press the "+" or "-" key until "rt" (return)
is displayed, at this point pressing the MENU (B) key returns you to the
USER MENU.
Pressing the ON-OFF/RESET (A) key you pass to the OFF state.
If no action is taken, once 2 minutes have passed the appliance exits
the menu and returns to the normal operation screen.
b
If you are replacing the electronic board it is necessary to set the
parameters 2 (11-13-17) and 4 (methane - lpg) depending on the
type of water heater used.
17
VALUES
FACTORY SETTING
11
13
17
0 (METHANE)
0 (methane models)
1 (LPG)
0 (FLOW SWITCH)
1 (FLOW INDICATOR)
(steps of 0.5s)
0 (NONE)
1 (ACTIVE)
0 (ABSOLUTE)
1 (CORRELATED)
NOT USED
11
13
17
1 (LPG models)
0
0.5s
65
1
0