Program Menu; Read Data From Repeater; Write Data To Repeater; Test Mode Window - Kenwood TKR-750 Programming Reference Manual

Hide thumbs Also See for TKR-750:
Table of Contents

Advertisement

7 PROGRAM MENU

7.1

Read Data from Repeater

This function allows to read the configuration data from
TKR-750/850/751/851 connected to the PC with the
KPG-46 programming cable by KPG-91D.
Connecting to the PC.)
Follow the procedures below to read the data.
1. Select one of the following options.
Select "Program" > "Read Data from Repeater".
Click
on the Toolbar.
2. Click "Read".
The PC starts reading the configuration data.
# If the Data Password is configured:
Click "Read" to view the "Data Password" window.
Figure 7-1 "Data Password" window
Enter the password in the "Data Password" edit
box and click "OK" to start reading the
configuration data.
Note:
! Embedded Message appears if the message has embedded
message.
! The error message appears if you enter a wrong password.
The "Data Password" window closes when entering an
incorrect password three times in a row.
The data reading completion message appears when
the PC correctly reads the confirmation from the
repeater.
3. Click "OK".
Note:
! The PC cannot read the configuration data when TKR-750/
850/751/851 does not respond even if "Read" is clicked. In
this case, you must ensure the power of TKR-750/850/751/
851 and the connection between the PC, and then start the
operation again.
! The error message appears when the Com port does not
open and you cannot read the configuration data. In this
case, you must ensure the COM port configuration in
"Communication Port", and then start the operation again.
(Refer to 9.1 Communication Port Window.)
60
7.2
This function allows to write the configuration data into
TKR-750/850/751/851 connected to the PC with the
(Refer to 1.2
KPG-46 programming cable by KPG-91D.
Connecting to the PC.)
Follow the procedures below to write the configuration
data.
1. Select one of the following options.
2. Click "Write".
The PC starts writing the configuration data.
# If the "Data Password" is configured:
3. Click "OK".
Note:
! The PC cannot write the configuration data when TKR-750/
! The error message appears when the COM port is not
7.3
It can configure the data used to perform various tests
and adjustments in the "Test Mode" window when
operating the TKR-750/850/751/851 in Test mode. In this
mode, you can make various adjustments, such as
checking the RF environment of the location and the
adjustment of the reception frequency, before installing or
operating the TKR-750/850/751/851. You can start the
test without writing data since the encode/decode
signalling and the test frequency are already configured.
(Refer to 6.13 Test Frequency Window.)
Field Programming Reference (FPRG)

Write Data to Repeater

Select "Program" > "Write Data to Repeater".
Click
on the Toolbar.
The warning message appears when clicking
"Write".
Figure 7-2 Warning message
Click "OK" to start writing the configuration data.
The data writing completion message appears
when the PC properly writes the confirmation.
850/751/851 does not respond even if "Write" is clicked. In
this case, you must ensure the power of TKR-750/850/751/
851and the connection between the PC and start the
operation again.
available and you cannot write the configuration data. In this
case, you must ensure that COM port is available in the
"Communication Port" configuration, and then start the
operation again.
(Refer to 9.1 Communication Port Window.)