Pv Program Vfo Limits - Kenwood TH-F6A Service Manual

144-/220/440 mhz fm tribander, 144/430 mhz dual bander
Hide thumbs Also See for TH-F6A:
Table of Contents

Advertisement

PV
Program VFO Limits
Description:
Displays the VFO limits for a band.
Function:
Displays a list of the band limits for A and B bands.
Send:
Status:
PV [band]
Modify:
PV [band],[f1], [f2]
Return:
PV [band],[f1], [f2]
Where:
[band]
see Band Table. Only used on A band.
[f1], [f2]
is a five (5)-digit frequency representing the lower and upper frequency
limits.
Notes:
This sets the limits used during VFO scans in the band.
Example:
Sent:
PV 0
Return:
PV 0,00137,00173
Sent:
PV 1,00216,00259
Return:
PV 1,00216,00259
Request VFO limit of 2 m band.
Transceiver says it's 137-173 MHz.
Set VFO limits of 1.25 m band.
Transceiver confirms limits of 216-259 MHz.
Menu Item #