Model SRK50ZSX-W, -WB, -WT
Outdoor
21˚CDB
23˚CDB
Air flow
air
14˚CWB
16˚CWB
temperature
TC
SHC
TC
10
5.63
4.44
5.90
12
5.53
4.39
5.80
14
5.43
4.34
5.70
16
5.32
4.28
5.59
18
5.21
4.23
5.48
20
5.10
4.17
5.37
22
4.98
4.12
5.25
24
4.86
4.06
5.14
26
4.74
4.00
5.01
28
4.61
3.94
4.89
30
4.49
3.88
4.76
Hi
32
4.35
3.82
4.63
14.3
34
4.22
3.75
4.49
3
(m
/min)
35
4.15
3.72
4.42
36
4.08
3.68
4.35
38
3.94
3.62
4.21
39
3.87
3.59
4.14
40
3.80
3.56
4.07
41
3.73
3.52
3.99
42
3.65
3.49
3.92
43
3.58
3.46
3.84
44
3.51
3.42
3.77
45
3.43
3.39
3.69
46
3.35
3.35
3.61
Model SRK60ZSX-W, -WB, -WT
Outdoor
21˚CDB
23˚CDB
Air flow
air
14˚CWB
16˚CWB
temperature
TC
SHC
TC
10
6.87
5.31
7.19
12
6.75
5.24
7.07
14
6.62
5.17
6.95
16
6.49
5.11
6.82
18
6.36
5.04
6.69
20
6.22
4.97
6.55
22
6.08
4.90
6.41
24
5.93
4.83
6.27
26
5.78
4.76
6.12
28
5.63
4.68
5.96
30
5.47
4.60
5.81
Hi
32
5.31
4.52
5.65
16.3
34
5.15
4.45
5.48
3
(m
/min)
35
5.07
4.41
5.40
36
4.98
4.37
5.31
38
4.81
4.29
5.14
39
4.72
4.25
5.05
40
4.64
4.20
4.96
41
4.55
4.16
4.87
42
4.46
4.12
4.78
43
4.37
4.08
4.69
44
4.28
4.04
4.60
45
4.13
3.94
4.44
46
3.85
3.72
4.15
Cooling mode
Indoor air temperature
26˚CDB
27˚CDB
28˚CDB
18˚CWB
19˚CWB
20˚CWB
SHC
TC
SHC
TC
SHC
TC
SHC
4.37
6.11
4.53
6.22
4.47
6.32
4.41
4.32
6.03
4.49
6.14
4.44
6.25
4.38
4.27
5.94
4.45
6.05
4.40
6.16
4.35
4.23
5.85
4.42
5.96
4.37
6.08
4.32
4.17
5.75
4.38
5.88
4.33
5.99
4.28
4.12
5.65
4.33
5.78
4.29
5.90
4.24
4.07
5.55
4.29
5.69
4.25
5.80
4.20
4.02
5.45
4.24
5.59
4.21
5.71
4.17
3.96
5.34
4.20
5.49
4.17
5.61
4.13
3.90
5.23
4.15
5.39
4.13
5.50
4.09
3.84
5.11
4.11
5.28
4.09
5.40
4.05
3.79
5.00
4.05
5.17
4.04
5.29
4.01
3.73
4.88
4.00
5.06
3.99
5.18
3.94
3.70
4.82
3.97
5.00
3.96
5.12
3.92
3.67
4.76
3.94
4.94
3.94
5.06
3.90
3.60
4.63
3.89
4.82
3.89
4.94
3.86
3.57
4.57
3.86
4.76
3.87
4.88
3.83
3.54
4.50
3.84
4.70
3.84
4.82
3.81
3.51
4.44
3.81
4.64
3.82
4.76
3.79
3.48
4.37
3.79
4.58
3.80
4.70
3.77
3.44
4.30
3.76
4.52
3.77
4.63
3.74
3.41
4.24
3.73
4.45
3.75
4.57
3.72
3.38
4.17
3.71
4.39
3.72
4.50
3.70
3.35
4.10
3.68
4.32
3.70
4.44
3.67
Cooling mode
Indoor air temperature
26˚CDB
27˚CDB
28˚CDB
18˚CWB
19˚CWB
20˚CWB
SHC
TC
SHC
TC
SHC
TC
SHC
5.22
7.46
5.39
7.58
5.32
7.72
5.25
5.16
7.35
5.35
7.48
5.28
7.62
5.21
5.09
7.24
5.30
7.38
5.24
7.52
5.17
5.03
7.13
5.25
7.28
5.19
7.42
5.13
4.97
7.02
5.20
7.17
5.15
7.31
5.09
4.90
6.89
5.15
7.06
5.10
7.20
5.04
4.84
6.77
5.09
6.94
5.04
7.08
4.99
4.77
6.64
5.03
6.82
5.00
6.96
4.94
4.71
6.51
4.98
6.70
4.95
6.84
4.89
4.64
6.38
4.92
6.57
4.90
6.71
4.84
4.57
6.24
4.86
6.44
4.84
6.58
4.80
4.49
6.10
4.80
6.31
4.79
6.45
4.74
4.41
5.95
4.74
6.17
4.73
6.31
4.68
4.38
5.88
4.71
6.10
4.70
6.24
4.66
4.34
5.80
4.68
6.03
4.67
6.17
4.63
4.27
5.65
4.61
5.89
4.61
6.03
4.58
4.23
5.57
4.58
5.81
4.59
5.95
4.55
4.19
5.49
4.55
5.74
4.56
5.88
4.52
4.15
5.41
4.52
5.66
4.53
5.80
4.49
4.11
5.33
4.48
5.59
4.50
5.73
4.46
4.06
5.25
4.45
5.51
4.47
5.65
4.43
4.03
5.17
4.41
5.43
4.44
5.57
4.41
3.93
5.02
4.32
5.28
4.34
5.42
4.31
3.71
4.71
4.09
4.96
4.11
5.09
4.08
(kW)
Heating mode (HC)
31˚CDB
33˚CDB
Air flow
temperature
22˚CWB
24˚CWB
TC
SHC
TC
SHC
6.51
4.55
6.69
4.42
6.44
4.52
6.62
4.39
6.37
4.50
6.55
4.37
Hi
6.29
4.47
6.48
4.35
17.3
6.21
4.44
6.41
4.32
3
(m
/min)
6.13
4.41
6.33
4.29
6.05
4.38
6.25
4.27
5.96
4.35
6.17
4.24
5.87
4.31
6.08
4.21
5.78
4.28
5.99
4.18
5.68
4.25
5.90
4.16
5.58
4.21
5.81
4.12
5.48
4.17
5.71
4.08
5.43
4.15
5.66
4.07
5.37
4.13
5.61
4.05
5.27
4.10
5.50
4.02
5.21
4.08
5.45
4.00
5.16
4.06
5.39
3.99
5.10
4.04
5.34
3.97
5.04
4.02
5.28
3.95
4.98
4.00
5.23
3.93
4.93
3.98
5.17
3.92
4.87
3.96
5.11
3.90
4.81
3.94
5.05
3.88
(kW)
Heating mode (HC)
Air flow
31˚CDB
33˚CDB
temperature
22˚CWB
24˚CWB
TC
SHC
TC
SHC
7.94
5.40
8.16
5.22
7.86
5.37
8.08
5.20
7.77
5.33
8.00
5.17
Hi
7.68
5.29
7.91
5.14
17.8
7.58
5.26
7.82
5.11
3
(m
/min)
7.48
5.22
7.73
5.08
7.38
5.18
7.63
5.05
7.27
5.15
7.53
5.02
7.16
5.11
7.42
4.97
7.05
5.06
7.31
4.94
Notes(1) These data show average statuses.
6.93
5.01
7.20
4.90
Depending on the system control, there may be ranges where the operation
6.81
4.97
7.08
4.86
is not conducted continuously.
6.68
4.93
6.96
4.82
These data show the case where the operation frequency of a compressor is
6.62
4.91
6.90
4.80
fixed.
6.56
4.88
6.84
4.78
(2) Capacities are based on the following conditions.
6.42
4.84
6.71
4.74
Corresponding refrigerant piping length :5m
6.36
4.81
6.65
4.69
Level difference of Zero.
6.29
4.79
6.58
4.67
(3) Symbols are as follows.
TC : Total cooling capacity (kW)
6.22
4.74
6.51
4.65
SHC : Sensible heat capacity (kW)
6.15
4.72
6.45
4.63
HC : Heating capacity (kW)
6.08
4.69
6.38
4.61
6.01
4.67
6.31
4.59
5.86
4.58
6.15
4.50
5.52
4.35
5.80
4.27
51
-
-
'18 • SRK-T-234
Outdoor
Indoor air temperature
air
16˚CDB
18˚CDB
20˚CDB
-20˚CWB
3.19
3.11
3.01
-15˚CWB
3.69
3.61
3.53
-10˚CWB
4.18
4.10
4.05
-5˚CWB
4.52
4.46
4.37
0˚CWB
4.74
4.67
4.59
5˚CWB
6.04
5.97
5.94
6˚CWB
6.14
6.07
6.00
10˚CWB
6.52
6.46
6.42
15˚CWB
7.10
7.04
6.99
20˚CWB
7.63
7.57
7.53
Outdoor
Indoor air temperature
air
16˚CDB
18˚CDB
20˚CDB
-20˚CWB
3.61
3.52
3.41
-15˚CWB
4.18
4.09
4.00
-10˚CWB
4.73
4.65
4.59
-5˚CWB
5.13
5.05
4.95
0˚CWB
5.38
5.30
5.20
5˚CWB
6.85
6.77
6.73
6˚CWB
6.96
6.88
6.80
10˚CWB
7.39
7.32
7.28
15˚CWB
8.05
7.98
7.92
20˚CWB
8.65
8.58
8.54
(kW)
22˚CDB
24˚CDB
2.94
2.85
3.45
3.38
3.95
3.86
4.32
4.25
4.54
4.47
5.82
5.74
5.92
5.85
6.34
6.27
6.91
6.85
7.45
7.39
(kW)
22˚CDB
24˚CDB
3.33
3.23
3.92
3.83
4.47
4.38
4.90
4.82
5.14
5.07
6.60
6.51
6.71
6.63
7.18
7.11
7.83
7.76
8.44
8.37