FLUID COMPATIBILITY
The 900 is compatible with the following fluids:
•Diesel Fuel, Gasoline, Kerosene, Mineral Spirits,
Heptane, and Hexane
The 900 is NOT compatible with the following fluids:
•Bleach, Hydrochloric Acid, Ink, Sulfuric Acid, and Salt
Water
If in doubt about compatibility of a specific fluid, contact
supplier of fluid to check for any adverse reactions to the
following wetted materials.
Ryton
Aluminum
Flourocarbon
Teflon®
ASSEMBLY & DISASSEMBLY
Meter consists of a chamber housing, measuring chamber,
gear train, counter assembly and cover. Meter can be
completely disassembled without disturbing piping.
Counter Assembly
For access to counter assembly, remove reset knob (item
15) by grasping edges and pulling firmly. Remove two
screws (item 14) and lift bezel (item 11) off. Remove two
screws (item 12) to detach counter face (item 13). Remove
two screws (item 9) to extract counter (item 10).
Reassemble by reversing procedure.
Meter Chamber Assembly
To expose meter chamber assembly, gear train and seal,
remove four screws (item 28). Meter chamber assembly
consists of upper and lower chambers, a nutating disc and
four screws. Meter chamber assembly (item 3) can be
dislodged by removing four screws (item 5). Reassemble by
reversing procedure.
If replacement of any components of the meter chamber
assembly is required, the complete assembly must be
replaced due to the precise method of its construction. This
assures a proper fit and a correctly operating chamber.
Gear Train and Seal
To disassemble gear train and seal, remove two screws
(item 8) and gear frame (item 6). Remove cluster gear (item
18), washer (item 19), and shaft (item 17). Remove drive
gear (item 24) and washers (item 23) by rotating and pulling
drive gear. Remove O-ring seal (item 25).
When reassembling seal, lubricate O-ring with oil or
petroleum jelly and replace in cover. Place washer on drive
gear shaft. Carefully rotate and push shaft through O-ring
and cover to prevent damage to O-ring. Shaft must then be
guided into pinion bevel (item 27) if counter has not been
removed. Replace remaining parts to complete assembly
by reversing disassembly procedure.
REPAIR
Meters needing repair should be taken to an authorized repair
shop. Meters must be thoroughly triple-rinsed before being
taken in for repair.
Stainless Steel
Buna N
Polyester
Nickel
PRIOR TO SERVICE, ADHERE TO FOLLOWING
INSTRUCTIONS:
Meters must be triple-rinsed and accompanied by a
note indicating the chemicals which have been
pumped through the unit. Meters not adhering to these
specifications may be refused service.
6.5"
16,5 cm
WHEN ORDERING REPAIR PARTS, BE SURE TO
GIVE REPLACEMENT PART NUMBER, DATE OF
MANUFACTURE AND METER SERIES NUMBER.
THIS WILL ENSURE THAT THE CORRECT
REPLACEMENT PART IS SUPPLIED.
TOLL FREE CUSTOMER CARE NUMBER
800 634 2695
900 SERIES REPAIR PARTS KITS
900KTF8119
Meter Repair Kit, U.S. Gallon (Standard Seals)
(Includes items 2-4, 6, 17-19, 21-25, 27, 30, 32)
900KTF8120
Meter Repair Kit, U.S. Gallon
(Fluorocarbon Seals)
(Includes items 2-4, 6, 17-19, 21-25, 27, 30, 32)
900KTF8121
Meter Repair Kit, Liter (Standard Seals)
(Includes items 2-4, 6, 17-19, 21-25, 27, 30, 32)
900KTF8123
Meter Repair Kit, Liter (Fluorocarbon Seals)
(Includes items 2-4, 6, 17-19, 21-25, 27, 30, 32)
901 METER KIT
901MK300
901 Meter Kit for FR300 Gallon
(Includes 901 meter with 800F4390 1 x 2 Nipple,
900F8082 Meter Flange)
901LMK300
901 Meter Kit for FR300 Liter
(Includes 901 meter with 800F4390 1 x 2 Nipple,
900F8082 Meter Flange)
901NMK300
901 Meter Kit for FR300 Gallon Nickel plated
(Includes 901 meter with 800F4390 1 x 2 Nipple,
900G9478 Nickel plated Meter Flange)
901MK4200
900 Meter Kit for FR4200 Gallon
(Includes 901 meter with 304F7924 1 x 5 Nipple,
1200F6732 1 x 4 Nipple, 304F7885 Elbow,
305F0998 Outlet Fitting)
901LMK4200
900 Meter Kit for FR4200 Liter
(Includes 901 meter with 304F7924 1 x 5 Nipple,
1200F6732 1 x 4 Nipple, 304F7885 Elbow,
305F0998 Outlet Fitting)
901NMK4200
900 Meter Kit for FR4200 Gallon Nickel plated
(Includes 901 meter with 304F7924 1 x 5 Nipple,
1200F6732 1 x 4 Nipple, 304F7885 Elbow,
900G9477 Nickel plated Outlet Fitting)