Control Panel Features and Functions

(A) Main Circuit Breaker
This 240V (30A) breaker will disconnect power to the
lights and auxiliary outlets. It will also disable the starting
circuit if engine starting is attempted when the main
breaker is on.
(B) Light Switches
One circuit breaker is supplied for each light.
(C) Ballast Indicator Lights
Indicates power from the ballast to each light.
(D) 240V Breaker
This 240V (30A) circuit breaker is supplied for the 240V
twist-lock receptacle.
(E) Engine Starting Switch
Keyed switch operates glow plugs, starts and stops
engine.
(F) Engine Hour Meter
Keeps track of engine hours for service.
Owner's Manual for MLT Light Tower
(G) DC Circuit Breaker
Circuit breaker (10A) for the engine electrical system.
(H) 120V GFCI Outlets
This unit is equipped with one 120V (20A) GFCI outlet to
supply power for accessories connected to the generator
when the engine is running and the main circuit breaker
is switched ON (I)
(I) 240V Twist-Lock Outlet
This 240V (30A) outlet supplies power for accessories
connected to the generator when the engine is running
and the main circuit breaker is switched to the ON (I)
position.
(J) 120V Breaker
This 120V (20A) circuit breaker is supplied for the 120V
GFCI duplex outlets.
(K) Circuit Breaker Indicator Light
This light indicates that the main circuit breaker must be
opened (switched off) before starting the engine.
General Information