Operation
NOTE: If oil pressure is not obtained within 15 seconds
after the key is switched to the "RUN" position, the low oil
automatic shutdown will turn off the fuel supply, stopping
the engine. Check the oil level and turn the key to the
"OFF" position to reset the oil pressure timer before
attempting to restart the engine.
GLOW
PLUG
Figure 3-5. Crank Engine
4. See
Figure
3-6. Release the key, it will move to the
RUN position.
CAUTION
Equipment Damage. Do not continuously crank
engine for more than ten seconds. Doing so will lead
to overdischarge of batteries and starter seizure.
OFF
GLOW
PLUG
Figure 3-6. Release Key
5. Once the engine is running, allow it to reach
normal operating temperature before switching on
any loads.

Automatic Shutdown

This unit is equipped with a low oil pressure and high
coolant temperature automatic shutdown system. This
system will automatically shut off the fuel supply to stop
the engine if oil pressure drops too low or the engine
20
OFF
RUN
START
003793
(000230)
RUN
START
003794
exceeds normal operating temperature. Return the main
circuit breaker to the OFF position to reset the unit after
the cause of shutdown has been determined.

Light Operation

WARNING
Burn hazard. Never operate lights with a
damaged or missing lens cover. Lamps are
hot and pressurized while in use. Unprotected
lamps can shatter, causing severe injury.
1. Verify the unit is on and running smoothly.
2. See
Figure
3-7. Switch the main circuit breaker (A)
ON (I).
3. Switch the individual circuit breakers for the lights
(B) ON (I), one at a time.
4. The ballast indicator lights (C) will turn on and
continue to get brighter as the lights warm up, and
then remain on. This confirms power is coming
from the ballasts to the lights.
A
MAIN
BREAKER
240V
ON
ON
ON
TURN
MAIN
BREAKER
OFF
120V
BREAKER
120V
NEUTRAL BONDED TO FRAME
Figure 3-7. Light Switches and Breaker
NOTE: If an indicator light does not turn on, see
Troubleshooting
or contact a Generac Mobile Products
Authorized Service Dealer.
NOTE: The lights require a warm up period of 5-15
minutes before they reach full output. If the lights are shut
down, they require a cool down period of approximately
ten minutes before they can be switched on again.
NOTE: The light tower uses four 1000W or 1050W
bulbs. When checking or replacing the bulbs, wipe them
with a clean cloth to avoid leaving any grease, oil residue
or fingerprints on the glass. Any residue can create a hot
spot on the bulb, causing premature bulb failure.
Owner's Manual for MLT Light Tower
(000277)
B
C
BALLAST INDICATOR LIGHTS
I
I
I
I
ON
ON
ON
O
O
O
O
MAST LIGHT SWITCHES
400W
400W
Flagger Station Switches
OFF
GLOW PLUG
GLOW
RUN
INDICATOR
PLUG
START
240V
DC
BREAKER
004548