Cable gland 1x M20x1,5 ( 2 atex version ) Operating Instructions 4. Description This level switch instruments for solids NSC, has been designed to be used in all applications where the level of the solid must be detected in tanks and silos. 5. Operating principle The NSC sensor together with the wall of the tank is a capacitor.
6. Mechanical connection The NSC has a thread of 1”BSP male. The sensitive part of the probe goes from the PP isolator to the end of the probe. Check that lenght of probe is according the level to be detected.
7. Electrical connection VERY IMPORTANT Be sure that power supply corresponds with the indicated in the equipment’s label. GREEN led lighting indicates that equipment is powered RED led lighting indicates that output relay is activated. Using SELECTOR 1, you can choose relay operation NO or NC when the product covers the probe.
8. Adjustment After installation and connection verification, we proceed to AJUST SENSITIVITY to fit the NSC with the tank and the product to measure. Check that product doesn’t reach the probe. Power supply GREEN LED must be ON 1. Put DIP-SWITCH 1 to “MAX” position.
Page 7
3. Turn slowly the “SENSITIVITY ADJUSTMENT screw” counter clockwise until RED LED switches off. 4. Turn 360º more counter clockwise to avoid a critical adjustment. In case of sticky products it is recommended to increase this adjustment. The instrument is now adjusted. When product will reach the probe relay will be activated and RED LED will light.
Module replacement MODCAP modules are delivered with DIP-SWITCHES 2, 3 and 4 adjusted with its own probe. In case of replacement, following procedure must be done with the probe free of product: 1. With DIP-SWITCH 1 to “MAX” and 2, 3 and 4 to “MIN”, turn the multiturn potentiometer totally to clockwise (20 turns).
9. Models There are 2 basic models of NSC: NSC..R The probe is a rod made of st.st. and covered with PTFE. It is used for minimum and intermediate level detection. It is produced a Standard version with a sensor of a maximum length of 3000mm NSC..C...
Sensitivity adjustment by multi-turn trimmer. Vdc polarity reverse protection. Minimum or maximum security adjustment. Rod version probe (NSC.R) covered with PTFE. Flexible cable st.st. probe (NSC.C) or steel covered with PP. ONLY ATEX VERSION: Certified: ATEX II 2/1 tD[iaD]iaD A21/20 IP65 T85 ºC Ta: -20ºC/+60ºC...
CE certificate type LOM 05ATEX2060 X. 2. General considerations. Operating principle of level switches NSC...EX is the capacity variation of the media when product is present. They are used for level control in hazardous zones.
Page 12
4. Chemical resistance: Verify that materials of the instrument are chemically compatible with the product to measure and application. 5. Special conditions for safe use: It is required for safety the adequate connection of protective conductor and the bonding to earth of the head box. Page 12 DT0307...
Installation in classified zone (ATEX) In classified zones, NSC. ATEX version, must be installed with the housing in zone 21,22 (category 2) or NOT CLASSIFIED. Process connection is mounted in the border wall between areas of category 2 and 1.
Inscription Certificazione per esame di tipo CE Marcatura LOM05ATEX2060X II 2/1 Ex tD[iaD]iaD A21/20 IP65 T85ºC Ta:-20ºC/+60ºC Fabricado en KOBOLD MESURA SLU Avda. Conflent, 68 nave 15 08915 BADALONA (Spain Made in: Hergestellt in: Fabriqué dans: Fabbricato in: Organismo notificado LOM 0163 Número notificación...