Download Print this page

BEVS 1306 User Manual

Intelligent pendulum hardness tester

Advertisement

Quick Links

Intelligent Pendulum Hardness Tester
BEVS 1306
User Manual
Please read the user manual before operation.
PAGE 1
Add:Floor3,Building A,No.257,Junye Road,Huangpu District,Guangzhou,China
E-mail:sales@bevsinfo.com
Http://www.bevsinfo.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1306 and is the answer not in the manual?

Questions and answers

Summary of Contents for BEVS 1306

  • Page 1 Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Add:Floor3,Building A,No.257,Junye Road,Huangpu District,Guangzhou,China E-mail:sales@bevsinfo.com Http://www.bevsinfo.com...
  • Page 2: Table Of Contents

    Content 1. Company Profile .................... 3 2. Product Introduction ..................3 3. Operation Instruction ..................4 4. Calibration ....................15 5. Maintenance ....................16 6. Order Information ..................17 PAGE 2 Add:Floor3,Building A,No.257,Junye Road,Huangpu District,Guangzhou,China E-mail:sales@bevsinfo.com Http://www.bevsinfo.com...
  • Page 3: Company Profile

    1. Company Profile BEVS Industrial Co., Ltd. is a leading developer & manufacturer that specializes in coatings, ink, painting, resin testing instruments and laboratory whole solution. We offer the complete and unique products in this field to meet customer's challenging demands of today and tomorrow, the products are complied with the standards of ISO, ASTM, DIN, BS, EN etc.
  • Page 4: Operation Instruction

    * High-precision guide rail ensures smooth movement and low noise. * 4.3 inch touch screen and user-friendly interface. * Data saved, and can be connected to a computer for output. 2.1 Technical Specification Dimension: L445*W350*H750mm(with cover open: 1270mm) Mass: 30kg Test Panel: L(70-200mm)*W(80-100mm)*H(1.5-10mm) Voltage: 100-230V(50/60HZ) Power: Max 50W...
  • Page 5 3.2.1 Please read all warnings on the instrument. 3.2.2 Ensure the voltage right. 3.2.3 Do not tear down the instrument on you own. 3.2.4 Organic glass cover can’t be move manually. 3.2.5 Be careful while taking the pendulum, it is sharp. Keep it good and get a new one while damaged.
  • Page 6 Figure 1 Shell KONIG Pendulum Touch Screen Hanging seat for pendulum Organic glass cover PERSOZ Pendulum Device of offsetting pendulum angle and Hanging seat for standard glass releasing Device of lifting the pendulum Adjustable footpad Power input 3.6.2 Explanation Under normal circumstances, Kö nig pendulum's result time is close to half of the PERSOZ pendulum's.
  • Page 7 determination of hard coatings, and the PERSOZ pendulum is more suitable for the determination of soft coatings. Due to the differences in structure, weight, size, oscillation period and swing between the two pendulums, and the complex elastic and viscous changes under the interaction between the pendulum and the coating, the two pendulums do not have equivalent conversion relationship of measurement results.
  • Page 8 If there is a warning, please adjust it. BEVS 1306 adopts high-precision electronic level meter to monitor the horizontal status. It can display the status of deviation from four foots. Adjust the four footpads to control the horizontal status.
  • Page 9 Figure 5 Figure 6 6) Pendulum type setting Please see below, choose the type you need. It is no need to set it when auto mode on. Figure 7 PAGE 9 Add:Floor3,Building A,No.257,Junye Road,Huangpu District,Guangzhou,China E-mail:sales@bevsinfo.com Http://www.bevsinfo.com...
  • Page 10 Figure 8 Auto mode will detect the pendulum type automatically. When the pendulum is placed correctly, the system will recognize and do the measurement accordingly. 7) Close the cover by clicking “Down” button. 8) Start measurement Start measurement (the instrument will check whether the above step has been executed), when the self-test passes, the test panel platform will be lifted, and test panel will hold up the pendulum to a limited height, pendulum separates from pins.
  • Page 11 When the test panel platform rises to a limited height, the waiting time (called the Y axis delay time) can be set up, and the free automatic dialing rod motor is then started to load the corresponding pendulum to a certain angle. Here we can set the waiting time (called the X axis delay time), then release the pendulum to start the swing motion of the pendulum.
  • Page 12 The correct placement of the Kö nig pendulum is the same as that of the PERSOZ pendulum. Please refer to the 3.6.3.4 instructions. The effect is shown in Figure 12. Figure12 Kö nig Pendulum test process is shown in Figure 13. The lever device will dial the swing pendulum to the position of 6 degrees, and then release the pendulum after the static setting, the pendulum will swing freely, and the counter and the timer begin to calculate at the same time.
  • Page 13 Figure14 Figure15 Factors that affect the results of the testing: *The level of the platform will affect the stability of the pendulum, and the level must be set as far as possible. *The presence of air will affect the oscillating period of the pendulum. The cover must be closed and keep the environment free from wind when working.
  • Page 14 *The swinging steel ball remains clean. Dirt or oil stains will affect the normal damping effect of the coating on the swing of the pendulum. 10) System Setting Click the setting button in main interface to enter the setting interface (Figure 6) click the system button to enter the system settings (Figure 16) to set the screen brightness and open or close the buzzer and open or close automatic energy saving Figure16...
  • Page 15: Calibration

    3.7 Instrument verification The verification of the instrument shall be carried out according to the requirements of the 3.6 operation guide, and the standard glass panel shall be used for operation. 3.7.1 The whole testing should be carried out under the conditions of laboratory temperature and humidity (temperature 23±2°C, relative humidity 50±5%).
  • Page 16: Maintenance

    4.6 The swings period cannot be changed by the pendulum. 5. Maintenance The regular maintenance is required for BEVS 1306 Intelligent Pendulum Hardness Tester. This responsibility is borne by the customer, not a warranty obligation. 5.1 The two steel ball of Pendulum is wiped only when it needs cleaning.
  • Page 17: Order Information

    6. Order Information BEVS 1306 Intelligent Pendulum Hardness Tester (K and P) BEVS 1306 /1 Intelligent Pendulum Hardness Tester (K) BEVS 1306 /2 Intelligent Pendulum Hardness Tester (P) PAGE 17 Add:Floor3,Building A,No.257,Junye Road,Huangpu District,Guangzhou,China E-mail:sales@bevsinfo.com Http://www.bevsinfo.com...