Viessmann VITODENS 200-W Service Instructions Manual page 72

Type wb2b, 45 and 60 kw wall mounted gas fired condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Fault
Const.
Weath.-
code
comp.
on the
display
28
X
30
X
X
38
X
X
40
X
48
X
50
X
X
58
X
X
72
System char-
Cause
acteristics
Regulates
System flow
without flow
temperature
temperature
sensor lead
sensor (low
broken
loss header)
Burner
Boiler water
blocked
temperature
sensor
shorted out
Burner
Boiler water
blocked
temperature
sensor lead
broken
Mixer closes
Heating cir-
cuit with
mixer M2
flow tem-
perature
sensor
shorted out
Mixer closes
Heating cir-
cuit M2 flow
temperature
sensor lead
broken
No DHW heat-
Cylinder
ing
temperature
sensor
shorted out
No DHW heat-
Cylinder
ing
temperature
sensor lead
broken
Measures
Check the low
loss header sen-
sor (see page 83).
Check the boiler
water tempera-
ture sensor (see
page 83).
Check the boiler
water tempera-
ture sensor (see
page 83).
Check the flow
temperature sen-
sor.
Check the flow
temperature sen-
sor.
Check the sensor
(see page 83).
Check the sensor
(see page 83).