Temperature-Limit; Update L3Plus - H3C S9500 Series Command Manual

Routing switches
Hide thumbs Also See for S9500 Series:
Table of Contents

Advertisement

Command Manual – Device Management
H3C S9500 Series Routing Switches
Moreover, after the schedule reboot at command is configured, and the system
time is adjusted by the clock command, the original schedule reboot at
parameter will become invalid.
Related commands: reboot, schedule reboot at, display schedule reboot.
Examples
# Configure the switch to be restarted after 88 minutes (the current time is 21:32).
<H3C> schedule reboot delay 88
Reboot system for 23:00:00 UTC 2006/11/1 (in 1 hours and 28 minutes)
Confirm? [Y/N]:y

1.1.14 temperature-limit

Syntax
temperature-limit slot-no down-value up-value
undo temperature-limit slot-no
View
User view
Parameters
slot-no: Physical card number.
down-value: Lower temperature limit, in the range 0°C to 70°C (32°F to 158°F).
up-value: Upper temperature limit, in the range 20°C to 90°C (68°F to 194°F).
Description
Use the temperature-limit command to configure temperature limit.
Use the undo temperature-limit command to restore temperature limit to default
value.
Examples
# Set the lower and upper temperature limit of card 0.
<H3C> temperature-limit 0 10 75

1.1.15 update l3plus

Syntax
update l3plus slot slot-no filename file-name ftpserver server-name username
user-name password password [ port port-num ]
Chapter 1 Device Management Commands