APPENDIx 3: OPTIONAL BLOWER INSTALLATION

A blower, sold separately, can be installed on the stove.
1.
Remove the backplate by cutting the knockouts with pliers.
2.
Screw the blower (A) in place using the screws (B) included in the installation manual.
Ensure that the blower's power cord is not in contact with any surface of the stove to
prevent electrical shock or fire damage. Do not run the power cord beneath the stove.
Page 44
MICROJOINTS
A
B