8.1.2
With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14 ½" (368 mm)
B
12" (305 mm)
C
13" (330 mm)
L
78" (1981 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
15
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
21" (533 mm)
F
21 ¾" (552 mm)
8.1.3
With Heat Shield AC02710 and Lowered Ceiling
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
2 ½" (64 mm)
B
2 ½" (64 mm)
C
2 ½" (64 mm)
78" (1981 mm)
L
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
15
above mentioned.
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe connector
16
to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
Page 30
USA
14 ½" (368 mm)
12" (305 mm)
13" (330 mm)
78" (1981 mm)
FROM PIPE CONNECTOR
USA
18" (457 mm)
21" (533 mm)
21 ¾" (552 mm)
USA
2 ½" (64 mm)
2 ½" (64 mm)
2 ½" (64 mm)
78" (1981 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
9 ½" (241 mm)
B
12" (305 mm)
C
13" (330 mm)
L
78" (1981 mm)
DISTANCES
FROM PIPE CONNECTOR
15
WITH DOUBLE WALL PIPE CONNECTOR
Canada
13" (330 mm)
D
E
21" (533 mm)
F
21 ¾" (552 mm)
16
DISTANCES FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
6" (152 mm)
E
11 ½" (292 mm)
F
11 ¼" (286 mm)
Installation and Operation Manual - Escape 1500
USA
9 ½" (241 mm)
12" (305 mm)
13" (330 mm)
78" (1981 mm)
USA
13" (330 mm)
21" (533 mm)
21 ¾" (552 mm)
USA
6" (152 mm)
11 ½" (292 mm)
11 ¼" (286 mm)