MAINTAINANCE
image 4.3.1

4.3 Replacing the filters

The lters are placed inside the oven. On the back of the oven there are two housings for holding the lters. The lters-houses can
be opened by hand. New lters can be ordered at www.technotape.com article: 3DT.SUB.AIR.FT1
NOTE: Always replace both lters at the same time.
Open both lter-housing endcaps with your ngers (see image 4.3.1). Place your hands within the grooves of the endcap and turn
clockwise. Unscrew the whole endcap and take out the lter (see image 4.3.2).
Replace the old lter for a new one. Tighten the endcap by hand, make sure that the seal ring is placed in the right groove (see
image 4.3.3).
image 4.3.2
image 4.3.3