Advertisement

User's Manual
PLEASE READ THE USER'S
MANUAL CAREFULLY BEFORE
USING THIS PRODUCT
Model number 2469MD
®
®
USE ONLY AS DIRECTED
If symptoms persist, consult
your healthcare professional

Advertisement

Table of Contents
loading

Summary of Contents for Actegy Revitive Circulation Booster

  • Page 1 ® ® User’s Manual USE ONLY AS DIRECTED PLEASE READ THE USER’S If symptoms persist, consult MANUAL CAREFULLY BEFORE your healthcare professional USING THIS PRODUCT Model number 2469MD...
  • Page 2: Table Of Contents

    Table of contents What is inside the box? Parts and Controls Introduction to REVITIVE Indications for use How REVITIVE works Important Safeguards 7-12 Contraindications Warnings Cautions Safety Precautions Adverse Reactions Instructions for use 13-25 How long should I use REVITIVE? Step 1: Setting up REVITIVE for the first time Step 2: Setting up the IsoRocker Step 3: Powering REVITIVE...
  • Page 3: What Is Inside The Box

    Parts and Controls of REVITIVE Medic What is inside the box? Parts of On opening the carton, please check that the following components Carry handle are provided. If you think anything is missing, please contact us using the REVITIVE Medic helpline numbers on the back of this booklet.
  • Page 4: Introduction To Revitive

    Introduction to REVITIVE IMPORTANT SAFEGUARDS INTENDED USE READ ALL INSTRUCTIONS BEFORE USE REVITIVE is intended to be used for electrical stimulation of the muscles of the lower leg for the purposes of supporting muscle function, and supporting WHO SHOULD NOT USE REVITIVE and improving blood circulation.
  • Page 5: Warnings

    IMPORTANT SAFEGUARDS WHO SHOULD CHECK WITH THEIR DOCTOR BEFORE • Do not apply foot-pads or Body Pads directly: USING REVITIVE • on open wounds or rashes, swollen, red, infected, or inflamed areas or skin eruptions (such as phlebitis, thrombophlebitis, varicose veins, cellulitis) •...
  • Page 6: Cautions

    IMPORTANT SAFEGUARDS Safety Precautions Cautions • Do not stand on the machine. Use only when sitting down • Be careful when applying stimulation: • over areas of skin that lack normal sensation - be careful not to • Use the device only for its intended purpose overstimulate the area.
  • Page 7: Adverse Reactions

    IMPORTANT SAFEGUARDS Instructions for use Adverse reactions How long should I use REVITIVE? • Skin irritation and burns beneath the electrodes have been reported with It is recommended to use REVITIVE for 20-30 the use of powered muscle stimulators minutes per day. •...
  • Page 8: Step 2: Setting Up The Isorocker

    Instructions for use STEP 2: STEP 3: SETTING UP THE ISOROCKER POWERING REVITIVE Turn the device over so that you can see the REVITIVE can be powered from either the rechargeable battery or by connecting IsoRocker and IsoRocker Disabler. it to an electrical socket. •...
  • Page 9: Step 4: Using The Foot-Pads

    Instructions for use STEP 4: USING THE FOOT-PADS Get into a comfortable seated position. Sit with MAINS POWER OPTION For best results sit with your knees at a 90 degree angle both bare feet (right angle). on the foot-pads If you want to use the REVITIVE when the battery is low or to preserve the battery level the REVITIVE can be used by connecting it to an Place REVITIVE on the floor in front of you.
  • Page 10 Instructions for use Use an intensity that provides you with strong but Set the time for REVITIVE. The default time is 30 comfortable muscle contractions and note that the minutes. You can set the timer for up to 60 minutes. intensity required may vary from day to day - eg using it If you do not want to use the default time of 30 minutes, on 25 one day, does not necessarily mean you will need...
  • Page 11: Step 5: Using The Electrode Body Pads

    Instructions for use STEP 5: USING THE ELECTRODE BODY PADS Select the area you wish to apply electrical stimulation to. REVITIVE comes with one pair of reusable (up to 20-30 applications) Body Pads that can be used to deliver electrical stimulation to the back, shoulders, thighs, knees or arms.
  • Page 12 Instructions for use Attach the ends of the Body Pads to the Body Pad Press the power button on the device or on the remote control to turn REVITIVE on. Cord. You will hear a beep and the display lights will light up. time will read 30 minutes and Intensity will read 00.
  • Page 13 Instructions for use Ensuring that the device has switched itself off, then Press the (+) Intensity Control until it is at the gently peel the Body Pads from the skin. desired level. Use an intensity that provides you with strong but Do not pull the Body Pads off the skin using the comfortable muscle contractions and note that the Body Pad cords as this may damage the cords.
  • Page 14: Step 6: Recharging The Battery

    Instructions for use STEP 6: STEP 7: RECHARGING THE BATTERY CLEANING AND STORING REVITIVE Ensure REVITIVE is switched off. REVITIVE can be powered from either the rechargeable battery or by connecting it to an electrical socket. Wipe down the foot-pads with a soft damp cloth. Locate the AC/DC power adapter.
  • Page 15: Troubleshooting

    Troubleshooting Problem Possible Cause Solution Problem Possible Cause Solution REVITIVE is on (lights Not placing both bare feet on the Ensure that your feet are bare No power or lights to AC adapter not switched on Check electrical socket power illuminated on the LED foot-pads at the same time.
  • Page 16: Technical Specifications

    Technical Specifications Frequency: Name of product REVITIVE Medic Foot: 20 to 43Hz, Body: 38 to 51Hz Model 2469MD Net Charge @ 500Ω [0.004]mC Weight 1.5kg Maximum Phase Charge @ 500 Ω Foot: 53µC Body: 17µC Maximum Current Density Foot: 0.032 mA/cm² Body: 0.100 mA/cm²...
  • Page 17: Symbols

    Symbols Contraindications, Warnings and Cautions 104°F Humidity and temperature limit for storage Make sure you understand these before using the REVITIVE 50°F Power Energy Efficiency Grade 5 Time Remaining Indoor Use Only Lead wires comply with the Performance Standard for electrode Intensity Level lead wires (21 CFR part 898) Battery Indicator...
  • Page 18: Warranty

    • The device is second hand. Subject to the exclusions set out below (see Actegy Ltd are not liable to carry out any Exclusions), the faulty device will then be type of servicing work, under the guarantee. repaired or replaced and dispatched usually within 7 working days of receipt.
  • Page 19 Toll free: 1-877-260-3114 Copyright © 2018 Actegy Ltd. All rights reserved. ACTEGY® and REVITIVE® and Circulation Booster® are registered trademarks of Actegy Ltd. The REVITIVE product is a proprietary design and is protected by applicable design laws. 2616_IFU03_15344797 P.D 06.2018...