New regulations (DIN 6868-157) in the dental market define strict standards for displays. It means you'll need a specific monitor, depending on the lighting conditions in your work environment. That's why Barco developed a range of displays for the dental practice. One for every environment. Ready to use out of the box.
Page 6
Welcome! Gives additional information about the described subject. Gives extra advice about the described subject. K5902134 /04 Nio Color 2MP 23"...
Welcome! 1.1 What's in the box Overview • 1x Nio Color 2MP 23" display • 1x stand base plate • 1x user guide • 1x system disc • 1x documentation disc • 1x video signal cable • 1x USB cable •...
Page 8
Welcome! • Turn left to scroll down in the OSD menu to decrease values in the OSD menu Front sensor Ambient light sensor Power status LED • Off: Display is in normal operation mode, or display is not powered • Blinking orange: Display is entering standby mode •...
Installation WARNING: Read all the important safety information before installing and operating your monitor. Please refer to the dedicated chapter in this user guide. WARNING: Sufficient expertise is required to install this equipment. All devices and complete setup must be tested before taking into operation. CAUTION: When the display is assembled in the medical system, take care of the fixation of all cables, to avoid unwanted detachment.
Installation 2.1 Stand base plate mounting To mount the stand base plate Put the display face down on a clean and soft surface. Be careful not to damage the panel. Rotate the stand pillar 90° counterclockwise. Image 2-1 Attach the stand base plate to the pillar by fixing the dedicated screw as shown below. Image 2-2 2.2 Cable connections To connect the cables...
Page 11
Installation Image 2-3 Connect the USB upstream connector to a PC USB host to make use of QAWeb or any of the display USB downstream connectors (e.g. to connect a keyboard, mouse or other peripheral). Image 2-4 Connect the mains power input to a grounded power outlet. Image 2-5 If necessary for your application, earth the Nio Color 2MP 23"...
Installation 2.3 Display position adjustment To adjust the display position You can safely tilt, raise and lower the display as desired. Image 2-7 CAUTION: Although the display can be physically rotated to portrait position, this mode is functionally not supported. 2.4 VESA-mount installation To mount the display on a VESA arm The display panel, standard attached to the stand, is compatible with the VESA 100 mm standard.
Page 13
Installation Use 4 M4 screws to attach the panel to a VESA approved arm. Please respect the following rule to select an appropriate screw length: • = T + W + 6 mm • = T + W + 14 mm Image 2-9 K5902134 /04 Nio Color 2MP 23"...
Page 14
Installation K5902134 /04 Nio Color 2MP 23"...
To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels. To learn more about LCD technology and missing pixels, consult the dedicated white papers available at www.barco.com/healthcare.
Operation To navigate the OSD menu • Turn the jog dial left or right to scroll through the different menu pages, to change values or to make selections. • Push the jog dial to go into a submenu or confirm adjustments and selections. 3.4 OSD menu locking/unlocking About To avoid unwanted or accidental activation of the OSD menu, a lock mechanism can be enabled.
DICOM: DICOM (Digital Imaging and Communications in Medicine) is an international standard that was developed to improve the quality and communication of digital images in radiology. In short, the DICOM display function results in more visible grayscales in the images. Barco recommends selecting the DICOM display function for most medical viewing applications.
Operation The available white point settings for your display are: • Native: The native, unmodified color temperature of the LCD panel. • 6500K: Corresponds to a color temperature of 6500 Kelvin (D65). • 7500K: Corresponds to a color temperature of 7500 Kelvin (D75). To select the white point Bring up the OSD main menu.
Page 20
Operation K5902134 /04 Nio Color 2MP 23"...
The Nio Color 2MP 23" does not require any scheduled maintenance or calibration activities. We recommend to use QAWeb with the Barco default tests and frequencies to calibrate and maintain the display, or to return the display to a Barco approved maintenance organization. In any case of doubts, please contact Barco Healthcare.
Important information 5.1 Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use. Electrical Shock or Fire Hazard To prevent electric shock or fire hazard, do not remove cover.
Important information Power cords • Europe: H05VV-F or H05VVH2-F PVC cord with appropriate EU plug. US and Canada: “hospital grade” cord-set has to be used, provided with instructions to indicate that grounding reliability can be achieved only when the equipment is connected to an equivalent receptacle marked hospital only or hospital grade.
Page 26
Electronic Products ” (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “General guidelines of environment-friendly use period of electronic information products” of Chinese Mainland.
The manufacturing country of the product is indicated on the product label (“Made in …”). Importers contact information To find your local importer, contact one of Barco’s regional offices via the contact information provided on our website (www.barco.com). FCC class B This device complies with Part 15 of the FCC Rules.
Page 29
Important information Electromagnetic emissions The Nio Color 2MP 23" is intended for use in the electromagnetic environment specified below. The customer or the user of the Nio Color 2MP 23" should assure that it is used in such an environment. Electromagnetic environment –...
Page 30
Important information Electromagnetic Immunity test Compliance level IEC 60601 test levels environment – guidance requires continued 0% residual voltage for 1 0% residual voltage for 1 operation during power period at 0° period at 0° mains interruptions, it is 70% residual voltage for 70% residual voltage for recommended that the Nio 25 periods at 0°...
Important information Test Immunity Maximum Distance frequency Band (MHz) test level (V/ Service Modulation power (W) (MHz) 5240 5100 – 5800 W LAN Pulse 802.11 a/n modulation 5500 217 Hz 5785 5.6 Explanation of symbols Symbols on the device On the device or power supply, you may find the following symbols (nonrestrictive list): Indicates compliance with Part 15 of the FCC rules (Class A or Class B) Indicates the device is approved according to the UL regulations Indicates the device is approved according to the UL regulations for Canada and US...
Page 32
Important information Caution: Federal law (United Stated of America) restricts this device to sale by or on the order of a licensed healthcare practitioner. Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the legal manufacturer Indicates the manufacturing date Indicates the temperature limitations for the device to safely operate within specs...
Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
Important information Patent protection Please refer to www.barco.com/about-barco/legal/patents 5.8 Technical specifications Overview Screen technology Active screen size 598 mm (23.6") (diagonal) Active screen size (H x V) 521 x 293 mm (20.5 x 11.5") Aspect ratio (H:V) 16:9 Resolution 2MP (1920 x 1080 pixels) Pixel pitch 0.2715 mm...
Page 35
QA software MediCal QAWeb Warranty Minimum 3 years, including 20,000 hours backlight warranty Please check the Barco Terms & Conditions for specific Warranty conditions. Operating temperature 0 °C to 40 °C (15 °C to 35 °C within specs) K5902134 /04...
Page 36
Important information Storage temperature -20 °C to 60 °C Operating humidity 8% to 80% (non-condensing) Storage humidity 5% to 85% (non-condensing) Operating pressure 70 kPa minimum Storage pressure 50 to 106 kPa K5902134 /04 Nio Color 2MP 23"...