Abnormal Horizontal Width - Tatung OMNISCAN SERIES Service Manual

Table of Contents

Advertisement

6.21 ABNORMAL HORIZONTAL WIDTH
READJUST
H.
SIZE
UP/DOWN CONTROL
I
I
I
CHECK H. SIZE SIGNAL
I
I
I
CHECK H. SIZE PRESET R481 - - -
1
1
I
CHECK MODE SIGNAL - - '
I
1
I
>
MICRO BOARD (PWB-1697-2)
PIN 2 P502
(OV TO 12V)
>
SEE ALIGNMENT
ITEM 2.3
>
HO, H1, H2
(PWB-1701)
CHECK 16V
-------------------------------->
0202
' I
(PWB-1701)
1
I
CHECK HOR.
-------------------------------->
0414, 0417, Q418
LINEARITY CIRCUIT
0412, 0420, 0421
I
RY401, L402, L405
I
(PWB-1701)
I
CHECK CS CAPACITOR
----------------------------->
C428, C429, C430
I
(PWB-1701)
I
I
CHECK H. SIZE - - - - - - - - - - - - - - - - - - - - - - - - '
->
0422, 0620a, 0620b
ADJ. 91RCUIT
0606a, 0607, 0608
I
T600, 0611, 0607
I
(PWB-1701 )
I
CHECK HIGH - - - - - - , - - - ,
VOLTAGE CIRCUIT
I
I
I
CHECK INPUT SIGNAL
VIDEO DISPLAY TIMING
1
I
I
CHECK DEF YOKE
I
I
I
END
------------->
HV: 26KV
=
6~20
=