0411 (2Sc4288A) Damaged Due To Surge Voltage - Tatung OMNISCAN SERIES Service Manual

Table of Contents

Advertisement

6.7 0411 (2SC4288) DAMAGED DUE TO THE SURGE VOLTAGE
TAKE OUT 0411
FROM MAIN BOARD
& POWER ON
I
I
INPUT 64KHz
SYNC. SIGNAL
I
I
I
CHECK VOLTAGE
------------------------>
0611, R666, D608, D606
SUPPLY CKT.
I
I
I
CHECK PWM
---------------------------->
PIN 2 OF T600
GENERATOR
SOUARE WAVEFORM
I
20Vp-p
I
NO
.
L _________________________________
>
R607, 0607, 0608, 0606a
:
0602, 0601, D600, 0603, 0605
I~
D~,~OO,D~,OOOO
I
CHECK FEEDBACK
---------------------->
USING 16V VOLTAGE TO SIMULATE
CIRCUIT
THE FEEDBACK VOLTAGE (ON PIN 3 OF 0620a)
I,
MEASURE THE WAVEFORM (PIN 2 OF T600)
THE WAVEFORM WILL CHANGE WHEN
:
16V (VIA 10Kohm RESISTOR) TOUCH PIN 3 OF 0620a.
I
NO
r--------------------------------->
0620a, 0620b, R602, D601
I
YES
I
I
CHECK HOR. DEF.
---'---------------------->
H. DY, L402, L405, C428
CIRCUIT
C429, C430
I
I
I
CHECK DPC BOARD ----------------------> GROUNDING TRACK
PWB-1732
I
I
I
I
I
CHANGE A NEW
2SC4288A
AND POWER ON
I
I
I
END
IF BREAK, THE PARABOLA SIGNAL
WILL GET TO H1, H2 SIGNAL LINE
VIA PINS 5,6 OF P310
THIS WILL CAUSE THE HOR. OSC
UNSTABLE AND DAMAGE THE 0411.
=
6-7
=