No Raster (H.def Failure) - Tatung OMNISCAN SERIES Service Manual

Table of Contents

Advertisement

6.4 NO RASTER (H.DEF FAILURE)
INPUT 64KHz
SYNC
I
SIGNAL
I
CHECK H. DEF.
OUTPUT PULSE
I
I
I
I
NG
I
CHECK VOLTAGE
SUPPLY CKT.
I
I
OK
- - > COLLECTOR OF 0411
(800 - 1000Vp-p) (SEE ITEM 6.5)
-------> HV. CKT FAILURE
> 0611, R666, 0608, 0606
R479,D411
CHECK PWM-------------------------> PIN 2 OF T600
GENERATOR
S~UARE
WAVEFORM
I
20Vp-p
I
NO
~------------'-------------> R607, 0607,0608, 0606a
I
0602, 0601, 0600, 0603, 0605
I
YES
0605, C603, 0602, 0603
I
CHECK FEEDBACK ----------------------> USING 16V VOLTAGE TO SIMULATE
CIRCUIT
THE FEEDBACK VOLTAGE (ON PIN 3 OF 0620a)
I
MEASURE THE WAVEFORM (PIN 2 OF T600)
I
THE WAVEFORM WILL CHANGE WHEN
I
16V (VIA 10 Kohm RESISTOR) TOUCH
I
PIN 3 OF 0620a.
I
NO
~
>
0620a, 0620b, R602, 0601
I
I
YES
I
CHECK HOR. DEF. - - - - - - - - - - - - - - - - - > H. DY, L402, L405, C428
CIRCUIT
C429, C430
I
I
CHECK DPC BOARD ----------------------> GROUNDING TRACK
PWB-1732
IF BREAK, THE PARABOLA SIGNAL
I
WILL GET TO H1, H2 SIGNAL LINE
I
VIA PINS 5, 6 OF P310
I
THIS WILL CAUSE THE HOR. OSC
I
UNSTABLE AND DAMAGE THE 0411.
I
CHANGE A NEW
2SC4288A
AND POWER ON
I
I
END
=
6-4
=