Microstep Resolution Selection - Motion DMD870 User Manual

Digital stepper drive
Table of Contents

Advertisement

DMD870 Digital Stepper Drive

Microstep Resolution Selection

When it's not in software configured mode, microstep resolution is set by SW5, 6, 7, 8 of
the DIP switch as shown in the following table:
Microstep
1 to 512
2
4
8
16
32
64
128
5
10
20
25
40
50
100
125
Motion Control Products Ltd.
User's Manual
Steps/rev.
(for 1.8°motor)
Default/Software
configured
400
800
1600
3200
6400
12800
25600
1000
2000
4000
5000
8000
10000
20000
25000
P a g e
SW5
SW6
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
| 1 1
www.motioncontrolproduts.com
SW7
SW8
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Advertisement

Table of Contents
loading

Table of Contents