7.Operating the solar charge controller

7.1 Factory Pre-Set configurations

With the factory pre-set configurations, the solar charge controller can be used in most applications without further
programming. On delivery, the controller is always set with these pre-set basic configurations that enable
immediate use of most typical solar systems after installation.
The solar charge controller can be reset to the factory pre-set configurations at any time with the Menu CONF.

7.2 Main Menu

Set values and functions can be adjusted with the four control keys on the panel. By pressing the key under the
MENU, a Main Menu appears in the display – Conf (System module settings), Prog (System parameter settings),
Load (Load mode settings) and Logg (Inquiry of internal data logger). By pressing the key below the corresponding
abbreviation, you can enter the corresponding menu (Figure 4: Programming Menu).
After entering the corresponding menu, the following actions can be set or viewed the appropriate information:
①You can use the keys ▲▼ to select sub-menu, and press the OK button to enter the sub-menu.
②After entering the sub-menu, press ▲▼ to change the value.
③After setting, press the OK button to save the set value, and return to the previous menu level.
④Pressing the MENU key will exit the setting, bring the display back to the normal Main Menu.
!
Note: 1.If you did not carry out any operation within 60s after
automatically exit the menu programming and the normal indication of running status appears .
no adjustments on an activated submenu value being changed, the display indication jumps to the main menu
and the adjustment in the open window is not stored or applicable.
Figure 4: Programming Menu
Battery type
Liquid
Nominal capacity
300Ah
Regulation
SOC
Factory adjust
Press OK+MENU
88% 12.7
26
I accu =
8.3A
OK
MENU
Conf
Load
Prog
Logg
OK
MENU
Float charge
13.7V
Boost charge
14.5V
Equal charge
14.8V
D/N threshold
3.0V
Disconnect
30%
Reconnect
50%
Page5/13 Pages
entering the setup menu
18
Load control
AUTO
Light on
delay
00:00
Light off
delay
00:00
Night timer 1
00:00
Night timer 2
00:00
, the controller will
2.If there are
Day
in
100
Ah
out
80
Total
in
1200
KAh
out
880