The table displays the total phase current for the immer-
sion heater at start up. If an immersion heater has already
been started and is not used for its full capacity the val-
ues in the table can be changed because the control
initially uses this immersion heater.
1x230V, F1155-6
Max electrical addition
(kW)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
1x230V, F1155-12
Max electrical addition
(kW)
0
1
2
3
4
5
6
7
Emergency mode
When the heat pump is set to emergency mode (SF1 is
set to
) only the most necessary functions are activated.
The compressor is off and heating is managed by the
immersion heater.
Hot water is not produced.
NOTE
The switch (SF1) must not be moved to " " or
"
" until F1155 has been filled with water.
Components in the product can be damaged.
Power in emergency mode
The immersion heater's output in emergency mode is
set with the dip-switch (S2) on the immersion heater
board (AA1) according to the table below. Factory setting
is kW for F1155.
NIBE F1155
Max phase current L1(A)
2.2
4.3
6.5
8.6
10.8
13.0
15.2
17.3
19.5
Max phase current L1(A)
4.3
8.7
13.0
17.4
21.7
26.1
30.4
1x230V for F1155-6
kW
1
2
0.5
on
off
1.0
off
off
1.5
on
off
2.0
off
off
2.5
on
off
3.0
off
off
3.5
on
off
4.0
off
off
4.5
on
off
1x230V för F1155-12.
kW
1
2
1
off
off
2
off
off
3
off
off
4
off
off
5
on
off
6
on
off
7
on
off
1x230V for F1155-6 / -12
AA1-SF2
The image shows the dip-switch (AA1-SF2) in the factory
setting, i.e. 3.5 kW for F1155-6 and 6 kW F1155-12 .
Emergency mode thermostat
The supply temperature in emergency mode is set using
a thermostat (FD1-BT30). It can be set to 35 (pre-set, for
example under floor heating) or 45 °C (for example radi-
ators).
För frånluftsvärme!
3
4
5
off
off
off
on
off
off
on
off
off
off
off
on
off
off
on
on
off
on
on
off
on
on
off
on
on
off
on
3
4
5
off
off
off
on
off
off
on
off
off
on
off
on
on
off
off
on
off
on
on
off
on
För markvärme!
K
L E
Chapter 5 |
Electrical connections
6
off
off
off
on
off
off
off
on
on
6
on
off
on
off
on
off
on
25