1234567
23º
ENANCER Electrónica S.A.
Rua Max Grundig 9
4705-820 Braga Portugal
Tel: +351 253 221 484

OTC-TERMO

When the OTC-TERMO is switched off, only the LED of the
panel is touched. This means that the only possible operation is switching the unit on
or off.
To switch on the unit press
switched on and the LEDs of some more keys light up.

Manual operation

The OTC-TERMO can operate in automatic and manual mode.
To operate in automatic mode it is necessary that the unit receives the date and
time. If this is not the case, the unit can only function in manual mode.
Since the OTC-TERMO does not have its own clock (there is no display for it) you
can receive the time signal from other units in the system. The ONLY units that send
time signals are the D-BUSDRV and the CENTRALSEC..
As such, when at least one of these units is placed in the system and the date and
time are adjusted, the OTC-TERMO receives the time signal.
If this is not the case, when you switch on the unit with the
manual mode. This is indicated by the LED of the
blinking.
blinking - unit switched on but climatization switched off
lights up - unit and climatization switched on
During manual functioning the ideal temperature is the one previously adjusted for
the respective season.
If desired you can change the target temperature by pressing the keys
or
to decrease the temperature.

Automatic operation

If the unit receives a time signal it goes to automatic operation when it is switched
on.
If the actual time is outside any defined operating period, the unit stays in STANDY
until an operating period starts.
In this case the
key stays off, indicating that climatization is switched off.
Pressing the
key switches the unit on in manual operation and the target
temperature is the defined ideal temperature. If necessary, climatization is switched
on.
As an alternative you can press
climatization is always switched on being the target temperature the actual
temperature plus (winter) or minus (summer) 1º.
When the time reaches an operating period, the defined target temperature of that
period is selected and the unit switches to automatic mode.
When the program ends, climatization is switched off.
To switch off the unit, press
: you will hear two beep tones indicating that the unit is
key that lights up or starts
in winter or
in summer. In this case
for more than 1 second.
key lights up when the
key, it goes directly to
to increase
Page 11 of 13