"Remaining" indicates how much space is left
to store ride data. The CycleOps PowerBeam
comes with enough room to store about 15 hours of
ride information. "Clear Ride Data" deletes all stored
rides on the CycleOps PowerBeam
Make sure you no longer need a ride or have down-
loaded it to your computer before choosing "Clear" .
Only the ride data is cleared; workouts uploaded
TM
from PowerAgent
, calibration information and
odometer data are still stored.
"Odometer" displays the total number of miles (or
kilometers) you have ridden on the CycleOps Power-
TM
Beam
Pro trainer.
5.3 Calibration
The CycleOps PowerBeam
calibrated at the factory. This enables it to accurately
measure power using similar technology to a power
meter. Rolling resistance is calibrated into the each
individual unit, but can vary depending on tire type,
tire pressure, clamping pressure and other condi-
tions. To obtain the most accurate results, follow the
subsequent guidelines:
Perform either the Roll Down Calibration or
Manual Calibration described below.
Infl ate tires to the rated pressure.
Attach the bicycle according to the instructions
in this guide (see Section 1.3).
TM
Pro
TM
Pro computer.
TM
Pro resistance unit is
Clamp the resistance unit to the rear tire accord-
ing to the instructions in this guide (see Section
1.3).
For mountain bicycles, use smooth tires. Knobby
tires are noisy and contribute to inaccuracies.
5.3.1 Roll Down Calibration
1.
Before entering the calibration routine, warm up
the CycleOps PowerBeam
ing the system for fi ve minutes.
2.
From the main menu, choose Setup Mode.
3.
From the setup menu, choose Calibration.
4.
From the calibration menu, choose Roll Down
Calibration.
5.
The CycleOps PowerBeam
struct you to pedal to 18 mph. Your current speed
is displayed as well.
6.
Once at 18 mph, hold this speed for two minutes.
A count down timer displays your remaining
time.
7.
After two minutes, immediately stop pedaling
and allow the system to coast to a complete stop.
8.
Do not touch or disturb the resistance unit while
the system is coasting. Do not pedal while the
system is coasting. Do not hit the brakes.
9.
After the unit comes to a complete stop, the
CycleOps PowerBeam
play "Calibration Passed." If you do not wait the
full two minutes or another issue occurs during
calibration, the CycleOps PowerBeam
puter will display "Calibration Failed." If calibra-
tion fails, repeat the calibration. If it continues to
fail, contact Saris Cycling Group.
10.
The unique rolling resistance calibration is now
incorporated into the factory calibration. This
calibration will remain in the system until anoth-
er calibration is performed.
TM
Pro and tires by rid-
TM
Pro computer will in-
TM
Pro computer will dis-
TM
Pro com-