6. Troubleshooting

Physical Tests

A FrameSaver 9123 unit's physical tests screen for the network interface is shown
below.
This example shows the Network Physical Tests screen, for the model with
64 PVCs and the FLEX SLV upgrade.
Physical Tests Screen Example
The ResetMon function key at the bottom of the screen only appears when a
Monitor 511 test pattern is Active. Select ResetMon to reset the monitor pattern
error counter.
6-20
Main Menu → Test → [Network Physical Tests/Data Port Physical Tests]
main/test/network
Device Name: Node A
Test
Local Loopbacks
Line Loopback:
Payload Loopback:
Repeater Loopback:
Remote Loopbacks
Send Line Loopback: Down
Pattern Tests
Send:
user-defined 0a0a
Monitor: user-defined 0a0a
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu
InjectErr
ResetMon
CAUTION:
You should not run these tests with frame relay equipment attached;
you must disconnect the frame relay equipment and use external test
equipment.
August 2001
NETWORK 1 PHYSICAL TESTS
Command
Status
Start
Inactive
Start
Inactive
Start
Inactive
Send
Inactive
Stop
Active
Stop
Active
9123-C-SLV
3/26/2000 23:32
Results
0:00:00
0:00:00
0:00:00
0:00:00
0:00:00 - Errors 99999+
0:00:00 - Errors 99999+
MainMenu
Exit