Read Controller Attributes - Omron KP**G-OD Series Communications Manual

Grid connect photovoltaic inverter
Table of Contents

Advertisement

3 Compoway/F
3-4-4

Read Controller Attributes

This service reads the model number and communications buffer size.
Command
 Service Request PDU
MRC
SRC
0
5
0
2
2
Response
 Service Response PDU
MRC
SRC
0
5
0
3
2
2
(1) Model data
The model is returned in 10 bytes of ASCII data. If the data is less than 10 bytes long, the remaining bytes will be
padded with spaces (20 hex).
Model
KPxxxx
(2) Buffer Size
The communications buffer size is expressed in 2-byte hexadecimal and is converted to 4-byte ASCII before
being displayed.
Model

KP40G / KP
KP100G
(3) Response Codes
Response
code
(MRES+SRES)
1001
Command too long
0000
Normal completion
3 - 14
3
Response code
(MRES+SRES)
4
Model data
KPxxxx(Space code)
Buffer Size
L
273bytes (0111)
417bytes (01A1)
Error name
The command is too long.
No error.
Grid Connect Photovoltaic Inverter KPG/KPL Communication Manual
Model data
Buffer size
10
Cause
4
Error
priority
1
None

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp**l seriesKp*l-od seriesKp40gKp100g

Table of Contents