  • Page 3: Features And Specifications

    Features & Specifications Features:   15 different functions including timers, switching, flashing, interval, random switching, …  Two pre-programmed delays.  Learning mode for delays of 2s up to 12 days.  Pushbutton control (with home modular light system K8006). ...
  • Page 4 Assembly hints 1. Assembly (Skipping this can lead to troubles ! ) Ok, so we have your attention. These hints will help you to make this project successful. Read them carefully. 1.1 Make sure you have the right tools:  A good quality soldering iron (25-40W) with a small tip.
  • Page 5: Assembly Hints

    Assembly hints 1.3 Soldering Hints : 1- Mount the component against the PCB surface and carefully solder the leads 2- Make sure the solder joints are cone-shaped and shiny 3- Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME ! AXIAL COMPONENTS ARE TAPED IN THE CORRECT MOUNTING SEQUENCE !
  • Page 6 Construction  R4 : 120K (1 - 2 - 4 - B) 1. Zener diodes. Watch the  R5 : 10K 6. IC socket. Watch the (1 - 0 - 3 - B) polarity ! position of the notch! 4. Metal film resistors ...
  • Page 7 Construction 9. Transistor. 12. Capacitor 14. Relay  T1 : BC547B RY...  RY1 : VR10V241C  C5 or eq. : 100nF / 250V 10. Pin header Choose operating voltage : 15. IC. Watch the position of  SK1 : 3p the notch! For 220-245VAC : ...
  • Page 8 Construction 16. Shunt for transient suppressor. The unit is equipped with a transient suppressor to reduce sparking. Normally, this suppressor is put over the relay contacts. In some cases it might be necessary to put it on the load (eg. with very small loads). ...
  • Page 9: Operation Mode

    Operation modes 17. Operation mode OPERATION DESCRIPTION MODE Momentary The load will be switched on as long as the pushbutton is pressed. mode Applications : doorbell, … Push once to turn on, push again to turn off the load. Applications : put a virtually unlimited num- Toggle mode ber of pushbuttons in parallel to control a light source or other device.
  • Page 10 Operation modes Push to turn on. After pre-set time has elapsed, load will turn off. Pushing the button during on-time Non-retrigger- has no effect. Load will turn off when pushbutton is held down and time elapses. Applications : able timer General timing.
  • Page 11: Operating Mode

    Operating mode Push to start the blinking action as described above. At release, the timer will start. When time Blinking circuit elapses, the load is turned off. A push during on-time restarts the timer. with timer Applications : warning lights, buzzers, … As long as the button is closed, the system will activate the output in a random manner (9 minutes to 2.5h between every transition).
  • Page 12: Learning Mode

    Learning mode 18. Learning mode The learning mode allows you to store two different delays, each from 2s up to 12 days. The delays are called delay1 and delay2. Originally, delay1 has been factory set to 3 minutes, while delay2 has been set to 30 minutes. All timer modes use delay1, unless the mode uses both delays.
  • Page 13 19. PCB...
  • Page 14 Diagram 20. Diagram VR10V241C 220/0.6W 220/0.6W 1N4148 LOAD LOAD 330K/0.6W IC1 PIC12CE518 VDR1 DATA VDR300 LED3RL 100nF/250V~ GP5/OSC1/CLKIN 470n/250V~ 120K 330K/0.6W PCB EDGE10 BC547 220/0.6W 1N4007 1N4007 SW DIP-4 100n 1N4007 1N4007 24V/1.3W 100µ/35V 5V1/0.5W 100µ/35V...
  • Page 16 VELLEMAN NV Legen Heirweg 33, B-9890 GAVERE Belgium (Europe) Modifications and typographical errors reserved © Velleman Components nv. H8008IP’2 - 2014 (rev.2) 5 4 1 0 3 2 9 3 1 5 6 2 7...