OIL DRAIN PROCESS
During the Oil Drain process, the recyclesolenoid is activated until there is greater than 1.1 bar
(16 psi) in the accumulator. The recycle solenoid is then deactivated and the oil drain solenoid is activated until
there is either a greater than 0.01 bar (0.15 psi) change per second in the accumulator or less than 0.62 bar (9 psi)
in the accumulator.
Figure 4-12. Oil Drain