Oil Drain - Bosch ACS 753 Repair Instructions

A/c service unit
Table of Contents

Advertisement

Plumbing and Mechanical
ACS 753, ACS 763, ACS 863 Service Manual
OIL DRAIN PROCESS
During the Oil Drain process, the recyclesolenoid is activated until there is greater than 1.1 bar
(16 psi) in the accumulator. The recycle solenoid is then deactivated and the oil drain solenoid is activated until
there is either a greater than 0.01 bar (0.15 psi) change per second in the accumulator or less than 0.62 bar (9 psi)
in the accumulator.
Figure 4-12. Oil Drain
92
SP00D00609
2018-03-26
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs 763Acs 863

Table of Contents