SINGLE ALARM SOUNDING PER ZONE
(Per Armed Period)
This field limits external alarm sounding to once per arming period for
a given zone. Enter 1 for yes; 0 for no.
U L
For UL installations, enter 0 for unlimited Alarm Soundings
29
FIRE SOUNDER TIMEOUT
This field determines whether the external sounder will shut off after
time allotted, or continue until manually turned off. Enter 0 for
sounder timeout, or 1 for no timeout. Default is 0.
30
ALARM BELL TIMEOUT
This field determines whether the external sounder will shut off after
time allotted, or continue until manually turned off. Entries are as
follows:
0 = No timeout; 1 = 4 min (default); 2 = 8 min; 3 = 12 min; 4 = 16 min.
36
EXIT DELAY
Exit delay defines the delay period that allows users to leave the
premises through a door that has been programmed as an entry/exit
delay door after arming the system without setting off the alarm.
Delay times are 00 (no delay) to 99 seconds.
37
ENTRY DELAY #1
The system will wait the time allotted before sounding alarm upon
entering through the designated main entry/exit door. The system
must be disarmed before an entry delay period ends, or an alarm will
occur. Delay time is selectable from 00 (no delay) to 99 seconds.
U L
For UL installations, entry delay can be no greater than 45 seconds.
38
ENTRY DELAY #2
The system will wait the time allotted before sounding alarm upon
entering through a designated secondary entry/exit location. The
system must be disarmed before an entry delay period ends, or an alarm
will occur. Delay time is selectable from 00 (no delay) to 99 seconds.
39
AUDIBLE EXIT WARNING (1-Digit Entry)
If enabled, this field provides exit warning sound when armed AWAY.
Warning sound consists of slow continuous beeps until last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of Exit time. 0 = no; 1 = yes.
40
PABX ACCESS CODE (See Box at Left)
Enter up to 6 digits if PABX is needed to access an outside line. If fewer
than 6 digits are needed to be entered, exit by pressing
number (e.g., 41). To clear entries from field, press 40 .
41
PRIMARY PHONE No. (See Box at Left)
Enter up to 20 digits. If fewer than 20 digits entered, exit by pressing
and next field number (e.g., 42). To clear entries from field, press 41 .
Note: Back-up reporting (8 calls are made to the secondary phone
number if no kiss-off is received after 8 attempts to primary number) is
automatic only if there is a secondary phone number (field 42).
42
SECONDARY PHONE No. (See Box at Left)
Enter up to 20 digits. If fewer than 20 digits entered, exit by pressing
and next field number (e.g., 43). To clear entries from field, press 42 .
See Note in field 41 also.
Note: To send a report to a pager, see field 47 on next page .