Electrical Data - Leuze electronic DLSP 160S Technical Description

Parallel optical data transmission
Table of Contents

Advertisement

5.4
Leuze electronic

Electrical data

Supply
Operating voltage
Residual ripple
Current consumption
Inputs
Data inputs (Data IN)
Transmit (TX)
Output enable (OE)
8 - 35 V
Fig. 12 Input circuit
Outputs
Data outputs (DO)
max. load
With a total data output load greater than 0.6 A, the back-up fuse triggers.
The supply voltage must be switched off and back on again one time in order to
activate the back-up fuse.
– Daten –
- Data -
Central short circuit
zentraler Kurzschluß –
Schutz
protection
6,8 k
Transient
Transienten-
protection
schutz
LED
Green
grün
Data valid (DV)
max. load
Fig. 13 Output circuit
DLSP 160S
16-35V DC
15%
appr. 130 mA (all LEDs on)
max. 35 V DC, 4.5 mA
H >= 8 V, L <= 5 V
H >= 8 V, L <= 5 V
C - MOS
6,8 k
LED Red
LED rot
High-side driver, short-circuit proof
H >= UB - 2V, L <= 1.5 V
2 outputs
each 250 mA
3 outputs
each 160 mA
4 outputs
each 120 mA
5 outputs
each 100 mA
6 outputs
each 80 mA
7 outputs
each 70 mA
8 outputs
each 60 mA
– Data valid (DV) –
- Data valid (DV) -
LED
High side driver, short circuit proof
250 mA
Short circuit
Kurzschluß –
Schutz
protection
LED
LED
Yellow
gelb
15