6.2
6.2.1
6.2.2
6.2.3
Leuze electronic
Commissioning
Setting the DLSP
➜
Setting the transmit and receive address.
➜
Setting the output storage characteristics.
speichern
nicht speichern
Do not store
Store
1
0
Fig. 15 Setting the DLSP
Performance test
➜
Switch on the supply voltage.
➜
Apply one or more input signals.
➜
Transmit data (input TX at "l").
The relevant input LEDs light up in red.
➜
Receive data (input Output enable at "1")
➜
Check receiver:
• the relevant output LEDs light up in green,
• the "Data valid" display lights up in yellow.
➜
Repeat the process for the other transmission direction.
Sensitivity adjustment
➜
Create the worst transmission conditions which can conceivably occur during
use:
• greatest possible distance,
• greatest possible lateral offset.
➜
At the first unit, remove the cover over the potentiometer for sensitivity ad-
justment.
➜
Turn the potentiometer as far to the right as it will go.
➜
Then turn the potentiometer slowly to the left until the display "Data valid"
goes out at the unit positioned opposite.
➜
Turn the potentiometer around back to the right by around 1/4 turn.
➜
Replace the cover over the potentiometer.
➜
Repeat the process at the other DLSP.
DLSP 160S
Empfangsadressen
Receive adresses
0
1
2
3
Sendeadressen
Transmit adresses
0
1
2
3
17