Electrical connection

5.1

Overview

The electrical connection of the device is performed using M12 connectors.
2
1
POWER
2
BUS
Fig. 5.1:
Position and designation of the M12 connections
Safety notices!
Ä Before connecting the device, be sure that the supply voltage agrees with the value printed
on the name plate.
Ä Only have the electrical connection performed by certified electricians.
Ä Ensure that the functional earth (FE) is connected correctly. Fault-free operation is only
guaranteed if the functional earth is connected properly.
Ä If faults cannot be rectified, take the device out of operation. Protect the device from acci-
dentally being started.
NOTICE
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
NOTICE
Protective Extra Low Voltage (PELV)!
The device is designed in accordance with protection class III for supply with PELV (Protective
Extra-Low Voltage).
NOTICE
Laying cables!
Ä Lay all connection cables and signal lines within the electrical installation space or perma-
nently in cable ducts.
Ä Lay the cables and lines so that they are protected against external damages.
Ä For further information: see EN ISO 13849-2, Table D.4.
Leuze electronic
1
CAUTION
DDLS 508
Electrical connection
37