Connections.

Motor-operated valves.

L
N
14 - ENGLISH
CLOSE
OPEN
U1

Phone dialler control.

It is possible to control the timer-thermostat remotely with a phone
dialler connected to the terminals .
By closing the contact, the thermostat is forced onto manual opera-
tion and the keys are locked .
On opening the contact the timer-thermostat is forced onto:
• Antifreeze mode if heating is on .
• OFF if air-conditioning is on . In this phase the keys of the timer-
thermostat are not locked and it is possible to operate the de-
vice .
actuator with clean contact