INSTALLATIoN

Maintenance

15. Maintenance
WARNING Electrocution
Before any work on the appliance, ensure omnipolar
disconnection from the power supply.
Draining the appliance
The appliance can be drained for maintenance work.
WARNING Burns
Hot water may escape when you drain the appliance.
f Close the 3-way shut-off valve or the shut-off valve in the
f
cold water supply line.
f Open all draw-off valves.
f
f Undo the water connections on the appliance.
f
f If dismantled, store the appliance in a room free from the
f
risk of frost, as water residues remaining inside the appli-
ance can freeze and cause damage.
Cleaning the strainer
If contaminated, clean the strainer in the threaded cold water
fitting. Close the 3-way shut-off valve or the shut-off valve in the
cold water supply line before removing, cleaning and refitting
the strainer.
16. Specification
16.1 Dimensions and connections
225
140
47
b03
b02
30
100
c06
c01
b02 Entry for cables I
b03 Entry for cables II
c01
Cold water inlet
c06
DHW outlet
32
| DHB-E SLi
≤ 20
105
35
114
DHB-E SLi
Male thread
G 1/2 A
Male thread
G 1/2 A
Alternative connection options
b04
b04
b02 Entry for cables I
b03 Entry for cables II
b04 Entry for cables III

16.2 Wiring diagram

3/PE ~ 380-415 V
1 Heater
2 High limit safety cut-out
3 Safety pressure limiter
Priority control with LR 1-A
2
1
1 Control cable to the contactor of the second appliance (e.g.
electric storage heater).
2 Control contact opens when switching the instantaneous
water heater on.
b04
47
b03
b04
b02
30
165
b04
DHB-E SLi
www.stiebel-eltron.com