STIEBEL ELTRON AUK 7 Operation And Installation
STIEBEL ELTRON AUK 7 Operation And Installation

STIEBEL ELTRON AUK 7 Operation And Installation

Fan convector

Advertisement

Quick Links

BEDIENUNG UND INSTALLATION
OPERATION AND INSTALLATION
UTILISATION ET INSTALLATION
KEZELÉS ÉS TELEPÍTÉS
KÄYTTÖ JA ASENNUS
GEBLÄSEKONVEKTOR | FAN CONVECTOR | VENTILO-CONVECTEUR | KLÍMAKONVEKTOR |
PUHALLINKONVEKTORI
» AUK 7
» AUK 14
» AUK 21
» AUK 28
» AUK 35

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUK 7 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STIEBEL ELTRON AUK 7

  • Page 1 BEDIENUNG UND INSTALLATION OPERATION AND INSTALLATION UTILISATION ET INSTALLATION KEZELÉS ÉS TELEPÍTÉS KÄYTTÖ JA ASENNUS GEBLÄSEKONVEKTOR | FAN CONVECTOR | VENTILO-CONVECTEUR | KLÍMAKONVEKTOR | PUHALLINKONVEKTORI » AUK 7 » AUK 14 » AUK 21 » AUK 28 » AUK 35...
  • Page 2: Table Of Contents

    12.2 Shutting off the throughput ���������������������������������� 11 Specification ������������������������������������������������ 12 13.1 Dimensions and connections ��������������������������������� 12 13.2 Wiring diagram for AUK 7 ������������������������������������� 13 13.3 Wiring diagram for AUK 14-35 ������������������������������� 14 13.4 Data table �������������������������������������������������������� 15 13.5 Output data ������������������������������������������������������ 16...
  • Page 3: General Information

    OPERATION GENERAL INFORMATION OPERATION 1.2.3 Keywords KEYWORD DANGER The keyword DANGER indicates information which must be General information observed, otherwise serious injury or death will result. WARNING The keyword WARNING indicates information that must be observed, otherwise serious injury or death may result. Document information CAUTION The keyword CAUTION indicates information that must be...
  • Page 4: Safety

    OPERATION SAFETY Safety Appliance description The appliance is a fan convector designed for wall mounting. A This appliance is designed for internal installation. heat exchanger draws heat from the heating circuit and transfers However, it must never be installed in wet areas. it to the ambient air.
  • Page 5: Frost Protection

    OPERATION OPERATION 4.1.2 Fan stage selector The right selector controls the air volume transported by the fan. It is a four-stage switch. These stages control the speed at which the appliance emits heat. We recommend operating the fan at the lowest stage. Although higher fan stages enable faster heat emission, they create louder fan noise.
  • Page 6: Cleaning, Care And Maintenance

    OPERATION CLEANING, CARE AND MAINTENANCE Cleaning, care and maintenance 5.2.2 Heavy duty cleaning » Switch the appliance OFF. WARNING » Wait until the fan has stopped. Risk to life through electrocution! Before any cleaning and maintenance work, isolate the appliance from the power supply. To ensure correct operation of the appliance, the following inspections and maintenance steps should be carried out.
  • Page 7: What To Do

    INSTALLATION WHAT TO DO IF ... What to do if ... Symptom Cause » Remedy The appliance is noisy Water circulating in the appliance can cause noise. The appliance is not faulty and no action is required. Depending on the fan speed selected, noises can occur The appliance is not faulty.
  • Page 8: Safety

    INSTALLATION SAFETY INSTALLATION Installation Installation location When selecting the installation location, observe the critical Safety environmental factors that influence the use of the appliance. Only qualified contractors should carry out installation, commissioning, maintenance and repair of the appliance. Critical Examples Application environmental General safety instructions...
  • Page 9: Inspection On Delivery

    INSTALLATION INSTALLATION Inspection on delivery » Upon receipt, immediately check that the delivery is complete and without transport damage. If you notice any transport damage, proceed as follows: - Do not accept the delivery or only accept it with reservation. - Note all damage on the delivery documentation or on the delivery slip of the carrier.
  • Page 10 INSTALLATION INSTALLATION 9.4.3 Drilling holes in the wall 9.4.5 Hooking the appliance into the mounting bracket You can use the mounting bracket as a template for the holes to be drilled. » Position the mounting bracket on the wall observing the minimum clearances (see chapter "Installation/Installation location") and mark the holes to be drilled.
  • Page 11 INSTALLATION INSTALLATION » On both the r.h. and l.h. side of the appliance, push a spring pin through the wall mounting bracket tabs that hook into the appliance. 9.4.7 Water connection When tightening the fittings, always counterhold with a tool. 1 Heating flow connection 2 Heating return connection There are heating system connections on both the l.h.
  • Page 12: Appliance Handover

    INSTALLATION APPLIANCE HANDOVER 10. Appliance handover 12. Cleaning, maintenance and repair » Explain the appliance function to users and familiarise them WARNING with its operation. Risk to life through electrocution! » Make users aware of potential dangers. Before any work on the appliance, disconnect all poles from the power supply.
  • Page 13: Specification

    INSTALLATION SPECIFICATION 13. Specification 13.1 Dimensions and connections AUK 7 AUK 14 AUK 21 AUK 28 AUK 35 Appliance Width 1090 1290 1490 Electrical cable entry Heating flow Male thread G 1/2 G 1/2 G 1/2 G 1/2 G 1/2...
  • Page 14: Wiring Diagram For Auk 7

    INSTALLATION SPECIFICATION 13.2 Wiring diagram for AUK 7 ϑ ∆ ϑ ∆ Room temperature controller Terminal 25 °C controller Terminal Hydraulic servomotor fan motor ON/OFF switch stage selector Microswitch |AUK WWW.STIEBEL-ELTRON.COM...
  • Page 15: Wiring Diagram For Auk 14-35

    INSTALLATION SPECIFICATION 13.3 Wiring diagram for AUK 14-35 ϑ ∆ ϑ ∆ Room temperature controller Terminal 25 °C controller Terminal Hydraulic servomotor Capacitor 1.0 µF fan motor Capacitor 1.0 µF ON/OFF switch Capacitor 1.0 µF stage selector Capacitor 1.5 µF Microswitch WWW.STIEBEL-ELTRON.COM AUK |...
  • Page 16: Data Table

    INSTALLATION SPECIFICATION 13.4 Data table AUK 7 AUK 14 AUK 21 AUK 28 AUK 35 227955 227956 227957 227958 227959 Outputs to EN 14511 Heating output, low 0,45 0,85 1,20 1,60 2,00 Heating output, medium 0,65 1,40 1,75 2,10 2,35...
  • Page 17: Output Data

    Fan stage 3 (high)) Fan stage 4 (max.)) Heating flow temperature[°C] Heating return temperature [°C] Air inlet temperature [°C] Air outlet temperature [°C] Heating output [W] 13.5.1 AUK 7 tv / tr 70 m³/h 70 m³/h 100 m³/h 100 m³/h 100 m³/h 100 m³/h...
  • Page 18 INSTALLATION SPECIFICATION 13.5.2 AUK 14 tv / tr 150 m³/h 150 m³/h 180 m³/h 180 m³/h 220 m³/h 220 m³/h 240 m³/h 240 m³/h °C °C Q [W] tL2[°C] Q [W] tL2[°C] Q [W] tL2[°C] Q [W] tL2[°C] 55/50 2009 53,3 2322 51,9...
  • Page 19 INSTALLATION SPECIFICATION 13.5.4 AUK 28 tv / tr 190 m³/h 190 m³/h 260 m³/h 260 m³/h 350 m³/h 350 m³/h 380 m³/h 380 m³/h °C °C Q [W] tL2[°C] Q [W] tL2[°C] Q [W] tL2[°C] Q [W] tL2[°C] 55/50 2519 52,9 3362 51,9...
  • Page 20 WARRANTY | ENVIRONMENT AND RECYCLING Guarantee The warranty conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products, it is increasingly the case that warranties can only be issued by those subsidiaries. Such warranties are only granted if the subsidiary has issued its own terms of warranty.
  • Page 21 NOTES WWW.STIEBEL-ELTRON.COM AUK |...
  • Page 22   Deutschland Verkauf Tel. 05531 702-110 | Fax 05531 702-95108 | info-center@stiebel-eltron.de STIEBEL ELTRON GmbH & Co. KG Kundendienst Tel. 05531 702-111 | Fax 05531 702-95890 | kundendienst@stiebel-eltron.de Dr.-Stiebel-Straße 33 | 37603 Holzminden Ersatzteilverkauf Tel. 05531 702-120 | Fax 05531 702-95335 | ersatzteile@stiebel-eltron.de Tel.