Carrier 40VM Series Installation And Operating Instructions Manual
Carrier 40VM Series Installation And Operating Instructions Manual

Carrier 40VM Series Installation And Operating Instructions Manual

Indoor fan coils vrf

Advertisement

Installation and Operating Instructions
CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
• INSTALLATION PREPARATION. . . . . . . . . . . . . . .3
• INSTALLATION PROCESS. . . . . . . . . . . . . . . . . . .3
• INSTALL THE PANEL. . . . . . . . . . . . . . . . . . . . . . . 5

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions which may cause death, personal injury or
property damage. The qualified installer or agency must use
factory-authorized kits or accessories when modifying this
product.
Follow all safety codes. Wear safety glasses, protective
clothing, and work gloves. Use quenching cloth for brazing
operations. Have fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local
building codes and the current editions of the National
Electrical Code (NEC) ANSI/NFPA (American National
Standards Institute/National Fire Protection Association) 70. In
Canada, refer to the current editions of the Canadian Electrical
Code CSA (Canadian Standards Association) C22.1.
Understand the signal words - DANGER, WARNING,
and CAUTION. DANGER identifies the most serious hazards
which will result in severe personal injury or death.
WARNING signifies hazards that could result in personal
injury or death. CAUTION is used to identify unsafe practices,
which would result in minor personal injury or product and
property damage.
Recognize safety information. This is the safety-alert
symbol (
). When this symbol is displayed on the unit and in
instructions or manuals, be alert to the potential for personal
injury. Installing, starting up, and servicing equipment can be
hazardous due to system pressure, electrical components, and
equipment location.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 18-40VMF3-01
Part Number 40VMF003---
Printed in U.S.A.
Form 40VMF3-1SI
40VM Series Indoor Fan Coil
VRF (Variable Refrigerant Flow) System
Outside Air Kit for 4-Way Cassette
Electrical shock can cause personal injury and death. Shut
off all power to this equipment during installation. There
may be more than one disconnect switch. Tag all
disconnect locations to alert others not to restore power
until work is completed.
When installing the equipment in a small space, provide
adequate measures to avoid refrigerant concentration
exceeding safety limits due to refrigerant leak. In case of
refrigerant leak during installation, ventilate the space
immediately. Failure to follow this procedure may lead to
personal injury.
Table 2 -Components Shipped with Unit
Name
Screw
4-Way Cassette
Outside Air Kit
Pg 1
WARNING
WARNING
Image
02-18
Replaces: New
Quantity
12
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40VM Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 40VM Series

  • Page 1: Table Of Contents

    40VM Series Indoor Fan Coil VRF (Variable Refrigerant Flow) System Outside Air Kit for 4-Way Cassette Installation and Operating Instructions Part Number 40VMF003--- CONTENTS WARNING SAFETY CONSIDERATIONS ....1 INSTALLATION .
  • Page 2 —— Details of the air inlet —— 4×M4 Foam Ø3 7/8 3 3/4 26 1/4 knocked out hole 16 1/2 3 1/8 NOTE: All Dimensions shown in inches 2 1/2 2 1/2 3 3/4 25 1/4 32 3/4 Fig. 2 —Dimensions 1-inlet -0.1 -0.2...
  • Page 3: Installation

    INSTALLATION Installation Preparation — 1. There are three fresh air openings on the different side of the kit as show on the Fig 4. 2. The inlet is a knockout. Select one, two, or three sides in advance and knockout the openings. 3.
  • Page 4 INSTALL 4-WAY CASSETTE OUTSIDE AIR KIT 1. Indoor unit wiring Before installing the outside air kit, complete the wiring to the control box according to the indoor unit manual. 2. Attach the outside air kit Before installing the outside air kit, align all of the openings before clipping on the kit as shown in Fig. 7, Section a. 3.
  • Page 5: Install The Panel

    Install the Panel — 4. Secure the panel (without the grille) onto the Outside Air Kit using M5 x 16 screws and washers. Before tightening the screws, be sure the panel is flush with the false CAUTION ceiling. See Fig. 12. •...
  • Page 6 © Carrier Corporation 2018 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 18-40VMF3-01 Printed in U.S.A. Form 40VMF3-1SI Pg 6 02-18 Replaces: New...

Table of Contents