The Evocool FFA1 has 4 multifunctional buttons (see red circled buttons in picture above).
Buttons functionality
1. POWER ON/OFF – SET button - lower left button
This button is used either to access the parameter list of the controller (for Certified Technicians only),
or to stop the operation of the cooler, except the lights.
Short press of the button: the controller will request a password to access the operating
parameter. This function is intended for Technicians only.
Long press (more than 3 sec): the controller will switch off the compressor, the fans and/or the
heater (if available). The lights may still be operating.
2. LIGHTS BUTTON OPERATION - upper left button
Lights status may be controlled by user overriding the controller logic.
Short press: toggles Lights On or OFF
3. ECO BUTTON (short or long press function) - upper right button
The ECO button offers two operation modes:
Short press:
The controller will revert to more relaxed thermostat settings, resulting in increased energy
saving.
Product temperatures will be stabilized at slightly higher levels.
If short pressed while in ECO mode, the controller will revert to NORMAL mode.
Long press (more than 3 sec)
Depending on the current status (DAY or NIGHT mode), the controller will revert to the
opposite mode. The controller will follow the respective logic of the active mode.
This action will be registered into controller's learning pattern.