Fike 204-0003 Twinflex Multipoint ASD Installation And Maintenance Instructions page 4

Detector, with sounder/strobe

Advertisement

Smoke mode 3 requires that the concentration of smoke is kept up for a longer period to trigger the device into alarm, so patience
is required. Small regular applications of test smoke are best in order to avoid drenching the detector as this may result in sticky
residues being left behind
Technical Data
Dimensions
Operating temperature
Operating Voltage Range
Operating Current
(no strobe version)
(strobe version)
LED Operation
Loading Units
(no strobe version)
(strobe version)
Volume Level
(@ 1m anechoic, Dual Tone)
Flammability
IP Rating
Part Codes
Product
204-0003
204-0001
204-0012
Technical Support
Contact your supplier for technical support on this product.
Due to the complexity and inherent importance of a life risk type
system, training on this equipment is essential, and commissioning
should only be carried out by competent persons. Fike cannot
guarantee the operation of any equipment unless all documented
instructions are complied with, without variation. This unit complies
with the EMC directive.
Fike's policy is one of continual improvement and the right to change
a specification at any time without notice is reserved. Whilst every
care has been taken to ensure that the contents of this document are
correct at time of publication, Fike shall be under no liability
whatsoever in respect of such contents. E&OE.
.
.............................................................................. 107mm diameter x 75mm
.............................................................................. -10
.............................................................................. 18V to 32V DC
Quiescent .............................................................. 56 uA (Typical)
End of line ON if applicable .................................... +50 uA (Typical)
Alarm Sounding – Sounder High ............................ 8.00 mA (Typical)
Alarm Sounding – Sounder Low ............................. 2.50 mA (Typical)
Alarm Sounding – Sounder Off .............................. 150 uA (Typical)
Alarm Activated ...................................................... 15.50 mA (Typical)
(in addition to Alarm Sounding)
Alarm Sounding – Sounder High ............................ 10.50 mA (Typical)
Alarm Sounding – Sounder Low ............................. 4.90 mA (Typical)
Alarm Sounding – Sounder Off .............................. 2.60 mA (Typical)
Alarm Activated ...................................................... 18.00 mA (Typical)
(in addition to Alarm Sounding)
Detector in Normal State (Smoke).......................... Flash at 20 second intervals
Detector in Normal State (Heat) ............................. Double flash at 20 second intervals
Detector at EOL ..................................................... Flash at 5 second intervals
Detector in Fault. ................................................... Flash at 1.3 second intervals
Detector Detecting Fire .......................................... Flash at 0.7 second intervals
Detector in Fire (once processed at panel) ............ Continuous
Max Loading Units per zone .................................. 27 SLU.............. 160 DLU
Sounder High ......................................................... 1.35 SLU ........... 8.0 DLU
Sounder Low ......................................................... 1.125 SLU ......... 6.5 DLU
No Sounder ........................................................... 0.5 SLU............. 1.0 DLU
Sounder High ......................................................... 2.7 SLU............. 16.0 DLU
Sounder Low ......................................................... 1.35 SLU ........... 8.0 DLU
No Sounder ........................................................... 1.35 SLU ........... 8.0 DLU
Sounder High ......................................................... 90+ dB(A) (For more information on sound output
Sounder Low ......................................................... 70+ dB(A) contact your supplier Ref 26-0747)
. ............................................................................. UL94-V2
. ............................................................................. IP 21C
No Sounder ........................................................... 204 0003
With Sounder ......................................................... 204 0001
With Sounder and Strobe ....................................... 204 0012
CPR Number
0832-CPR-F0123
0832-CPR-F0124
0832-CPR-F0125
o
o
C to +50
C
V3 Panel:
Pro Panel:
Fike Safety Technology Ltd
Unit 31, Springvale Ind. Est.
Torfaen, NP44 5BD
DoP-204-0001, DoP-204-0003, DoP-204-0012
EN54-3: 2001 +A1: 2002 +A2: 2006, EN54-5 : 2000 +A1: 2002,
EN54-7: 2000 +A1: 2002 +A2: 2006,
Sounder Technical Data: See 26-0747
204-0001, 204-0003, 204-0012
Intended for use in the fire detection and fire alarm
Systems in and around buildings
Essential characteristics
Nominal activation conditions / Sensitivity, Response
delay (response time) and Performance under fire
conditions
Operational reliability
Tolerance to supply voltage
Durability of operational reliability and response delay,
Temperature resistance
Durability of operational reliability, Vibration resistance
Durability of operational reliability, Humidity resistance
Durability of operational reliability, Corrosion resistance
Durability of operational reliability, Electrical stability
Durability of operational reliability, Resistance to ingress
0832
14
Performance
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
26-0947 Issue 10
31/07/18