Section 2: General Information; Specifications - Generac Power Systems Magnum MLT3060M Owner's Manual

Light tower
Table of Contents

Advertisement

Section 2: General Information

Specifications

DESCRIPTION
Engine
EPA Tier
Fuel Consumption—100% Prime
Fuel Consumption—75% Prime
Fuel Consumption—50% Prime
Battery Type—Group Number
Battery Voltage
Battery Rating
Generator
Output - Standby
Output Voltage
Output Amperes 120V (240V)
Frequency Hz
Weights
Dry Weight
Operating Weight
Capacities
Fuel Tank Volume
Usable Fuel Volume
Coolant (including engine)
Oil (including filter)
Maximum Run Time
AC Distribution
Circuit Breaker Size
Trailer
Hitch—Standard
Maximum Tire Pressure
Specifications are subject to change without notice.
Owner's Manual for MLT3060M-K Light Tower
UNITS
gph (Lph)
gph (Lph)
gph (Lph)
quantity per unit
amp-hours
kW (kVA)
volts
120/240, single phase
amperes
Hertz
lbs (kg)
lbs (kg)
gal (L)
gal (L)
qt (L)
qt (L)
hours
amperes
psi (kPA)
MLT3060M
4f
0.47 (1.78)
0.35 (1.32)
0.24 (0.91)
24
12V (1)
440 CCA
6.0 (6.0)
120/240, single phase
50 (25)
60
1640 (744)
1856 (842)
30 (114)
30 (114)
4.5 (4.3)
3.8 (3.6)
64
30
2 in. Ball
50 (345)
General Information
MLT3060K
4f
0.50 (1.89)
0.38 (1.44)
0.25 (0.95)
24
12V (1)
440 CCA
6.0 (6.0)
50 (25)
60
1657 (752)
1873 (850)
30 (114)
30 (114)
4.8 (4.5)
5.4 (5.1)
60
30
2 in. Ball
50 (345)
13