C. Optional LOG BUS Wiring
The K-1900-3 transmits 1200 baud ASCII data from the
LOG BUS screw terminals. Log Bus data is sent each
time there is an entry point event, and includes the tenant
memory location number dialed and whether the guest
was allowed to enter, or the keyless entry code dialed and
whether it was valid or not.
DB-9
(not included)
Pin 2
(Receive
Data)
If the RS-232 input of a PC, printer, etc. is capable of
receiving TTL level RS-232 signals, then the LOG BUS
can be wired directly into the RS-232 "Receive Data"
and "Signal Ground" pins to receive ASCII data.
Windows "Hyper-Terminal" can be used to receive the
data on a PC (use the settings in the chart) or visit
www.vikingelectronics.com to download free ENTRY
LOGGER software (see Operation section E, "Entry
Logger Software").
A. Accessing the Programming Mode
1. Remote Programming
Step 1.
Connect the LINE IN port to a C.O. line or analog PABX/KSU station.
Step 2.
From a touch tone phone, call the line connected to the K-1900-3.
When the K-1900-3 answers, enter "Q" followed by the six digit security code, factory set to
Step 3.
845464 (see section B). A double beep will indicate that programming has been entered.
Step 4.
Program as shown in sections B - G.
To exit programming, enter "##7" or do not enter any touch tones for approximately 20
Step 5.
seconds. Three beeps will be heard, followed by an automatic disconnect.
2. Local Programming Using the Security Code (from entry phone)
Step 1.
Take the phone connected to the PHONE port off-hook.
Enter a "Q" followed by the six digit security code, factory set to 845464 (see section B). A
Step 2.
double beep will indicate that programming has been entered.
Step 3.
Program as shown in section B - G.
Step 4.
To exit programming, hang up the entry phone (push the "Call" button on the K-1700-3).
Pin 5
(Signal
Ground)
H
Brown (Receive Data)
L
Yellow (Signal Ground)
Programming
VIKING
LINE IN
1610m (5280 ft - 1 mile) maximum
run length using 24 gauge wire
Communication Software Configuration
Com
Baud Rate
Data Bits
Stop Bits
Parity
Flow Control
3
MODEL K-1900-3
©
VIKING
ELECTRONICS
HUDSON, WI 54016
APARTMENT ENTRY
SYSTEM
PROGRAM
PHONE
1
1 2 3 4 5 6 7 8 9 10
Your serial port (1-4)
1200
8
1
none
none