3.
4.
Open the screws (M6x16) which fix the
connection bolts (which connects the
cassette to the diffuser frame) and remove
the bolts.
The cassette can now be lifted out of the
diffuser frame.
Before installing the new cassette on the
diffuser frame, check the diffuser status.
Depending on their status, recovery or
mechanical diffuser cleaning might be
necessary (please refer to our diffuser
maintenance document TSG-C-WW002).
Prepare the new module as descripted above
(install lifting eye bolts and prepare lifting
tool)
Leave the packaging of the module if
possible till final installation into the tank, this
will minimize the risk of membrane damage
during handling with the lifting tool
Make sure the lifting equipment does not
touch the white membrane sheets when
being attached to the module
Form-No: TI-WW006 // Revision: B // Date: Jul. 5, 18
7 | 13