Microdyn Nadir Bio-Cel L-1 Technical Instructions page 10

Replacement of cassette and diffuser

Advertisement

2.
3.
4.
For a diffuser replacement you would need spare part 00350120 (BIO-CEL® L-1 Set of 7 tube diffusers
including connectors and sealing). The Set consists of the parts shown in Table 4.
No
Picture
1
2
3
Table 4: Content of diffuser set
Description
Diffusor tube Length (L)
Connector for diffusor tube
L
= 127 mm
total
¾" external thread
Blind cap incl. flat seal
Form-No: TI-WW006 // Revision: B // Date: Jul. 5, 18
Open the screws (M6x16) which fix the
counter part of the diffuser tubes and remove
it.
Disassemble the blind cap with the special
socket wrench.
If there are round shaped blind caps (older
systems) use a pipe wrench to remove it..
Remove the double threaded connector with
the blind plug from the opposite side of the
distributor pipe and lift out the diffuser tube.
Amount
7
7
7
10 | 13