Power Supply Unit 1360-PK-055 (1954-00-002)

Mounted in Non Hazardous Area.

I.S. LVPCI may be used with either Model 1360 IS Anemometer (SIRA 00ATEX2218, IECEx SIR
13.0157) or IS II Anemometer (SIRA 15ATEX2014 and IECEx SIR 13.0013).
I.S. Rating – ATEX European, IECEX International.
NOT for use in Zone 0, 1 and 2 Areas (Non Hazardous Area Use Only).
See ATEX and IECEX Certificates in Appendix 2.
Input and Outputs
Digital Input
Digital Outputs
Power Requirement
Input Power
Output Power
Dimensions
Size
Weight
Materials
External Construction
Environmental
Moisture protection
Ambient Operating temperature
Storage Temperature
Humidity
EMC
Intrinsic Safety
EN60079-0:2012
EN60079-11:2012
EN60079-26:2007
IEC60079-0:2011 Edition 6.0
IEC60079-11:2011 Edition 6.0
IEC60079-26:2006 Editions 2.0
Standards
Site Calibration
Intrinsically Safe WindObserver Anemometer
Doc. No. 1360-PS-0001
RS422 Interface (Data to/from IS WindObserver connected via
galvanic isolation).
RS232 and RS422 Interface (Data to/from IS WindObserver)
9v to 30v dc at 200mA max (Fused 20mm, 1 amp, anti-surge).
Galvanic isolation between input power and anemometer supply.
10.5v dc at 50mA to IS WindObserver (fused 100mA)
See page 13 for dimensions.
2.4kg.
Fibox Euronord Polyester
IP54
-30°C to +40°C
-50°C to +75°C
5% to 90% RH
Emissions and Immunity
Emissions
Immunity
Traceable to UK national standards
None required.
Page 9
EN 61326-2-1:2013
EN 61204-3:2000
EN 60945:2002 Clause 9
EN 60945:2002 Clause 10
May 2015