Table of Contents
3
1 Foreword
6
2 Introduction
6
3 Fast Track Set-Up
6
4 Specification
7
5 Pre-Installation
8
Equipment Supplied
8
Installation Requirements
8
6 Installation
10
Installation Guidelines
10
Bench System Test
11
Cabling
11
Connections
12
Default Settings
13
Connecting to a PC with a RS422 or RS485 Input
14
Networking Units
15
Connecting to a PCI Unit with RS422 Input
16
Indoor Power and Communications Interface (Part 1189-PK-021)
16
PCI Electrical Power Requirements
16
PCI Connector Pin and Cable Assignments
17
Anemometer Connector - 15 Way
17
Auxiliary Analogue Outputs - 9 Way
17
DC Supply - 4 Way
17
RS 232 Output - 9 Way
18
RS422 Network in - 9 Way Skt
18
RS422 Network out - 9 Way Plg
18
Analogue Connections
19
Analogue Voltage Output Connections (5V or ± 2.5V)
19
Analogue Connections for 4-20Ma Output
19
Power Supplies
20
Mechanical Installation
21
Location
21
Orientation
21
Mounting Bracket
21
Alignment
23
Figure 2B Windobserver II Outline Dimensions
24
7 Using with the Gill Winddisplay
25
Connecting to a Gill Winddisplay
26
8 Message Formats & Options
27
Wind Speed Format
27
Output Formats
27
Low Wind Speeds
27
Networking
28
Units
29
Output Rate
29
Sample Average
29
Averaging (Digital Data)
29
Options
29
Speed of Sound (SOS) and Temperature
29
Heating (if Fitted)
30
Offset
30
Vertical Output Padding
30
Doc. No. 1390-PS-0004 January
30
ASCII Message Format (UV and Polar)
31
ASCII UV Format
31
ASCII Polar Format
32
Binary Message Format (UV, Polar and Tunnel)
33
Binary UV Format
33
Binary Polar Format
33
Binary Tunnel Format
34
NMEA Format
35
Analogue Outputs and Options
36
Output Modes
36
Channel Outputs
36
Status
36
Temperature
36
Tunnel Mode
36
Scaling
36
Averaging
36
Polar Mode Direction Wraparound
37
Low Wind Speeds
37
9 Configuring
38
Entering Configuration Mode
38
Returning to Measurement Mode
38
Checking the Configuration
39
Changing Settings
39
Configuration Settings
39
Ax - Speed of Sound (SOS) and Temperature
39
BX - Baud Rate
40
CX- Analogue Output Polar Mode Direction Wraparound
40
DX- Diagnostic and Configuration Command (See also Section 10.6)
40
Ex - Full Duplex/Half Duplex Mode
41
Fx- Data and Parity Options
41
Gx to Gxxxx - Averaging (Digital Outputs Only)
41
Hx - Heating (if Fitted)
41
Jx - Analogue Power-Up Tests
41
Kx - NMEA Settings
42
Lx - ASCII Message Terminator
42
MX to MXX - Message Format
42
Nx - Node Address
42
Ox - ASCII Output Format (Output String Padding)
43
Px - Output Rate
43
Q- Measurement Mode
43
Tx - Analogue Output Voltage or Current Settings (if Fitted)
43
Ux - Digital Output Units
43
VX- Vertical Output Padding
43
45° Alignment Offset/Inverted Operation
44
Yx - Analogue Output, Channel 3 (if Fitted)
45
Zx - Analogue Output Scaling (if Analogue Outputs Fitted)
45
10 Maintenance & Fault-Finding
46
Cleaning and Handling
46
Servicing
46
Fault-Finding
46
Returning Unit
47
Status (Error) Codes
47
Bench Test
47
Integrity Check Chamber (ICC)
48
Integrity & Zero Wind Check
48
11 Appendices
49
Glossary & Abbreviations
49
Guarantee
50
Principle of Operation
51
Doc. No. 1390-PS-0004 January
51
Electrical Conformity
52
Advertisement
Gill Instruments WindObserver II User Manual (41 pages)
Ultrasonic Anemometer (Pipe Mount)
Brand:
Gill Instruments
| Category:
Measuring Instruments
| Size: 1.68 MB
Table of Contents
Table of Contents
3
1 Foreword
5
2 Introduction
5
3 Fast Track Set-Up
5
4 Specification
6
5 Pre-Installation
7
Equipment Supplied
7
Installation Requirements
7
6 Installation
8
Installation Guidelines
8
Bench System Test
9
Cabling
9
Connections
10
Factory Default Output Settings
10
Connecting to a PC with a RS422 or RS485 Input
11
Networking Units
12
Connecting to a PCI Unit with RS422 Input
13
Indoor Power and Communications Interface (Part 1189-PK-021)
13
PCI Electrical Power Requirements
13
PCI Connector Pin and Cable Assignments
14
Anemometer Connector - 15 Way
14
Auxiliary Analogue Outputs - 9 Way (Not Applicable to Pipe Mount Unit)
14
DC Supply - 4 Way
14
RS 232 Output - 9 Way
15
RS422 Network in - 9 Way Skt
15
RS422 Network out - 9 Way Plg
15
Mechanical Installation
16
Location
16
Orientation
16
Mounting Bracket
16
Power Supplies
16
Alignment
17
7 Using with the Gill Winddisplay
18
Connecting to a Gill Winddisplay
19
8 Message Formats & Options
20
Wind Speed Format
20
Output Formats
20
Low Wind Speeds
20
Networking
20
Units
21
Output Rate
22
Sample Average
22
Averaging
22
Options
22
Speed of Sound (SOS) and Temperature
22
Heating
22
45 Offset
22
Vertical Output Padding
22
ASCII Message Format (UV and Polar)
23
ASCII UV Format
23
ASCII Polar Format
24
ASCII Polled (UV and Polar)
24
Binary Message Format (UV, Polar and Tunnel)
25
Binary UV Format
25
Binary Polar Format
26
Binary Tunnel Format
26
NMEA Format
27
9 Configuring
28
Configuring Using Hyperterminal
28
Entering Configuration Mode
28
Returning to Measurement Mode
28
Checking the Configuration
29
Changing Settings
29
Configuration Settings
30
Ax - Speed of Sound (SOS) and Temperature
30
BX - Baud Rate
30
CX - Not Applicable
30
DX - Diagnostic and Configuration Command
31
Ex - Duplex Mode
31
Fx - Data and Parity Options
31
Gx to Gxxx - Averaging (Digital Outputs Only)
31
Hx - Heating
32
Jx - Not Applicable
32
Kx - NMEA Settings
32
Lx - ASCII Message Terminator
32
MX to MXX - Message Format
32
Nx - Node Address
33
Ox - ASCII Output Format (Output String Padding)
33
Px - Output Rate
33
Q - Measurement Mode
33
Tx - Not Applicable
33
Ux - Digital Output Units
33
VX - Vertical Output Padding
34
45 Alignment Offset/Inverted Operation
34
Yx - Not Applicable
34
Zx - Not Applicable
34
10 Maintenance & Fault-Finding
35
Cleaning
35
Servicing
35
Fault-Finding
35
Returning Unit
36
Status (Error) Codes
36
Bench Test
36
Integrity Check Chamber (ICC)
37
Integrity & Zero Wind Check
37
11 Appendices
38
Glossary & Abbreviations
38
Guarantee
39
Principle of Operation
40
Electrical Conformity
41
Ec Declaration of Conformity According
41
Issue
41
Gill Instruments WindObserver II User Manual (33 pages)
Ultrasonic Anemometer
Brand:
Gill Instruments
| Category:
Measuring Instruments
| Size: 0.47 MB
Table of Contents
Table of Contents
3
Foreword
5
Introduction
5
Fast Track Set-Up
5
Specification
6
Pre-Installation
7
Equipment Supplied
7
Installation Requirements
7
Installation
8
Installation Guidelines
8
Bench System Test
9
Cabling
9
Connections
10
Power Supplies
12
Mechanical Installation
12
Location
12
Orientation
12
Mounting Bracket
12
Alignment
14
Message Formats & Options
16
Wind Speed Format
16
Output Formats
16
Output Format
16
Units
16
Output Rate
17
Sample Average
17
Averaging
17
Heating
17
45° Offset
17
Vertical Output Padding
17
ASCII Message Format (UV and Polar)
18
ASCII UV Format
18
ASCII Polar Format
19
NMEA Format
20
Configuring
21
Entering Configuration Mode
21
Returning to Measurement Mode
21
Checking the Configuration
22
Changing Settings
22
Output Format
22
Unit Identifier
23
Units
23
Output Rate
23
Averaging
23
Heating
23
Nmea
23
Vertical Output Padding
23
45° Offset
24
Communications Settings
25
Baud Rate
25
Duplex Mode
25
Data and Parity Options
25
ASCII Message Terminator
26
Scaling
26
Polar Mode Direction Wraparound
26
Configuration and Diagnostic Information
26
Message Format (Output String Padding)
26
Maintenance & Fault-Finding
27
Cleaning
27
Servicing
27
Fault-Finding
27
Returning Unit
28
Status (Error) Codes
28
Bench Test
28
Integrity Check Chamber (ICC)
29
Integrity & Zero Wind Check
29
Appendices
30
Glossary & Abbreviations
30
Guarantee
31
Principle of Operation
32
Electrical Conformity
33
Ec Declaration of Conformity According
33
Advertisement
Advertisement
Related Products
Gill Instruments WindMaster PRO
Gill Instruments WindMaster RA
Gill Instruments WindMaster Pipe Mount
Gill Instruments WindMaster
Gill Instruments 1086-G-045
Gill Instruments 1210-PK-065
Gill Instruments 1210-PK-066
Gill Instruments 1210-PK-085
Gill Instruments 1360-G-026
Gill Instruments 1360-G-028
Gill Instruments Categories
Measuring Instruments
Weather Station
Network Router
Switch
Wireless Router
More Gill Instruments Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL