DI−410
INSPECTION PROCEDURE
Check voltage between terminals +B and E1 of ECM connector.
1
E5
E1
(−)
NG
2
Check for open in harness and connector between terminal E1 of ECM and body
ground (See page IN−30).
OK
3
Check voltage between terminal IGSW of ECM connector and body ground.
NG
DIAGNOSTICS
PREPARATION:
Turn the ignition switch to ON.
E3
CHECK:
Measure the voltage between terminals +B and E1 of the ECM
connectors.
OK:
(+)
+B
B17411
PREPARATION:
Turn the ignition switch to ON.
E3
CHECK:
Measure the voltage between terminal IGSW of the ECM con-
nector and body ground.
OK:
IGSW (+)
B17411
−
ENGINE (1GR−FE)
Standard: 9 to 14 V
OK
Proceed to next circuit inspection shown in the
Problem symptoms table (See page DI−33).
NG
Repair or replace harness or connector.
Standard: 9 to 14 V
OK
Go to step 6.