Digital Display; Configuration Parameters - Bunn ThermoFresh Series Use & Care Information Manual

1.0 & 1.5 gallon servers with digital sight gauge or mechanical sight gauge
Hide thumbs Also See for ThermoFresh Series:
Table of Contents

Advertisement

DIGITAL DISPLAY

The Digital Sight Gauge (DSG) senses liquid levels and monitors hold times.
Horizontal bars indicate the liquid level. The 1.0 gallon sensor displays a total of 4 bars and the 1.5 gallon sensor
displays 6 bars. Each bar represents approximately 32 ounces of liquid. All bars will be displayed when the
server is full. As liquid is dispensed the number of bars displayed decreases beginning with the upper most bar.
When the server is close to empty no bars are displayed.
Hold times are displayed by a freshness timer. As liquid level increases,
the DSG Display will show 1 Bar, and the freshness timer will show
the initial value (4:00 for default count down timer). As the liquid level
continues to increase, typical during a brew, the timer may reset on
every bar increase, depending on the length of time it takes to increment
to the next bar. When the liquid level has stabilized, the timer will start
counting down in 1 minute increments until the server is empty or the
time has expired. Whenever the liquid level is decreased to zero bars
the timer is replaced with three dashes.
Warning of freshness time expiration is indicated by the timer flashing as it continues to count (flashing from
2:00 until 0:00 is the default setting).
A status LED will flash to indicate the liquid level is near empty (zero bars), the freshness time warning has been
reached or the freshness time has expired.

CONFIGURATION PARAMETERS

These parameters define how the digital display functions.
Configuration
Parameter
Freshness Time
Duration
Flashing Notification
Time
Freshness Timer
Direction
Status LED
Rotary
Switch
Access
Values (Default setting is bold)
0:30, 1:00, 1:30, 2:00, 2:30, 3:00, 3:30, 4:00
Yes
Off, 0:30, 1:00, 1:30, 2:00, 2:30, 3:00, 3:30, 4:00
Yes
Yes
Off –Timer is disabled
Up – Timer counts from 0:00 to FTD
Down – Timer counts down from FTD to 0:00
Yes
Off – Status LED is Disabled
Freshness Time Expired
Flashing Notification
Server Empty
Freshness Time Expired & Server Empty
Flashing Notification & Server Empty
8
FIG. 1
Display
Ftd...2:00...
Fnt...oFF...
Fnt...0:30..
dir...oFF...
dir...up...
dir...dn...
LEd...oFF...
LEd...Ft...
LEd...Fn...
LEd...E...
LEd...FtE...
LEd...FnE...
54923 041118