Eggtimer Proton Airstart Quick Reference
General Rules for Successful Airstarts
 SIMULATE EVERYTHING FIRST!!!
 Your booster motor's thrust:weight ratio should ideally be 10:1 or above.
 Your separation time should be at least 120% of the motor's burn time.
 You should fire the sustainer's igniter at least ½ second after separation, longer is OK.
 Don't use high-thrust motors like VMax's in the booster.
 If you expect your booster to get you near mach, increase the sample rate and reduce the
LDA altitude to ensure that the timer is triggered.
 Use an altitude or velocity qualification if your booster motor's thrust:weight is < 10:1 or
your stability is < 2C, or if you're waiting an extended amount of time before firing the
sustainer motor.
Proton Airstart Functions
Drogue/Main Timer:
Values: OFF (default), Nose-Over (Drogue only), 0.3-3.0 by .1 secs, 3.2-9.8 by .2 secs
Controls when after launch the timer will fire the channel
Drogue/Main Min Alt:
Values: OFF (default), 300'-3000' by 100', 3200'-9800' by 200'
Controls the MINIUM ALTITUDE that must have been reached for the channel to
fire
Drogue/Main Alt Chk:
Values: @Timer (default), Anytime
Controls when the ALTITUDE CHECK is performed:
 @ Timer: When the timer expires
 Anytime: Anytime up to when the timer expires
Drogue/Main Min Vel.:
Values: OFF (default), 100-1000 fps by 100 fps, 1200-2000 fps by 200 fps
Controls the MINIMUM VELOCITY that must have been reached for the channel to fire
Drogue/Main Vel. Chk:
Values: @Timer (default), Anytime
Controls when the VELOCITY CHECK is performed:
 @ Timer: When the timer expires
 Anytime: Anytime up to when the timer expires
Drogue/Main Pulse Width:
Values: 1-9 sec (default 2 sec)
Controls the amount of time that the channel fires
Drogue/Main Use BW:
Values: NO (default), Yes
Controls whether or not the hardware breakwire is tested at firing time
- 53 -