Troubleshooting - Viking 40-IP Product Manual

Ip ceiling speaker for sip endpoint paging or multicast paging / background music
Hide thumbs Also See for 40-IP:
Table of Contents

Advertisement

If the unit cannot register with the programmed SIP server, the LED will blink on and off every two seconds until communication
is restored. This alerts a potential user of a problem with the device that will prevent a page from being made.
Optional Secure Remote Relay Control using Viking Model RC-4A
For applications requiring secure relay control a Viking model RC-4A remote relay controller can be used. The relay controller
is mounted securely inside the building and connected to the same LAN as the 40-IP. The 40-IP will send an encrypted
message to the RC-4A to activate its relays which control the door strikes/gates.
Up to 4 40-IP's can communicate with one RC-4A allowing you to securely control four entrances.
When using an RC-4A for remote relay control the 40-IP's relays must be set to "External"(see Programming section 12).
See DOD 582 for more information.
12V DC Adapter
(included)
Door / Gate Examples:
Door near Speaker 1
Relay 1 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Doorstrike,
120V AC
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
Connectors (included)
Gate near Speaker 2
Relay 2 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Gate Controller, etc.
Gate Controller
(Power typically not
required for gate controllers)
Door near Speaker 3
Relay 3 Output Contacts
(5A@30VDC / 250VAC max)
120V AC
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
2 Gel-Filled Butt
Connectors (included)

Troubleshooting

VIKING
RELAY CONTROLLER
IN1 C IN2 IN3 C IN4
RELAY 1
RELAY 2
1
4
5
2
3
LED 2
LED 1
COM.
N.O.
2 Gel-Filled Butt
COM.
N.O.
2 Gel-Filled Butt
Connectors (included)
COM.
N.O.
MODEL RC-4A
©
VIKING
ELECTRONICS
HUDSON, WI 54016
NETWORK ENABLED
1
2
3
4
5
6
STATUS
LED
RELAY 3
RELAY 4
LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
SPARE
6
7
8
9 10 11 12
1 2 3 4
NETWORK
LED 9
LED 6
LED 7
LED 5
LED 8
LED 3
LED 4
on
1
2
3
4
Sensor
Examples:
Door Sensor
Gate Sensor
Door Sensor
Door Sensor
Door near Speaker 4
Relay 4 Output Contacts
250VAC max) Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Connectors (included)
19
SIP VoIP PBX,
SIP Cloud based
Service Provider
Switch
or
PC with SIP
Server Software
PoE
Switch
IN1 C IN2 IN3 C IN4
1
2 3 4 5 6
(5A@30VDC /
COM.
Doorstrike /
N.O.
Magnetic Lock
2 Gel-Filled Butt
Internet
40-IP
Speaker 1
40-IP
Speaker 2
40-IP
Speaker 3
40-IP
Speaker 4
120V AC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pa-ip