CH1. Temperature 302°F / Air Flow 100,
CH2. Temperature 572°F / Air flow volume 120,
CH3. Temperature 842°F / Air flow 180

PROGRAMMING

CH1 to CH3 are the three programmable settings
Press the SET key to adjust the desired airflow for CH1. The digits will start to flash and
the air volume can be adjusted from 0-200. Without adjustment, CH1 and the
temperature will start to flash when you press the SET button.
Press the SET key again to adjust the temperature of CH2. Then press SET to adjust
the air flow of CH2. Press SET to adjust the temperature of CH3. Press SET again to
adjust the air flow of CH3. Press SET again to Switch between temperature readings in
°C or °F. After all the changes have been entered, press ENTER again to store the
program settings.
***Note: You cannot adjust airflow to zero. Generally the higher the temperature,
the higher the airflow to prolong the life of the heating element.***
Faster. Smarter. Better.
To set: Hold down the SET button on the
screen and the green button on the wand
handle simultaneously for two seconds. Once
the indicator is released, the blue numbers 00
will start flashing.
This figure is used to reset the temperature.
Use the ↑ and ↓ symbols below the CH to
adjust the desired temperature. The adjustable
temperature range is 212°F - 932°F.